A. Introduction
Welcome to the Quadra-Fire family. This manual will help
you understand and operate the wall control attached to
yournewpelletAdvancedEnergyappliance.
TheQuadra-Fire WallControlis not just atraditional ther-
mostat,butanintegralpartofthepelletappliancesystem.
While it has many of the features one would expect from
an advanced thermostat, including programmable setback
capabilitiesandcurrenttemperaturedisplay,italsoindicates
thesystem’scurrentoperatingcycleandstate.Itdoesthis
by communicating with the appliance via a wired connec-
tion.
Additionally,itallowsyoutosetparametersthatwilloptimize
theperformanceofyourpelletappliancesystem.Thesepa-
rametersareaccessedwithaneasytonavigatemenusys-
tem.
READY
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
Current Time
System Status
Current Set
Temperature
Current
Temperature
Function Labels for the Function Buttons
Notifications
Icons
Figure 2.1
Figure 2.2
B. The Main Screen
Thekeytobeingcomfortablewhileoperatingyournewwall
controlis to familiarize yourselfwith the main screen.The
mainscreenshows,ataglance, the statusofthesystem,
themostimportantsettingsandthecurrenttemperature.Ad-
ditionally,themainscreenindicateswithsimpleiconsmany
useractionsrequiredtokeepyourapplianceworkingasin-
tended. Figure 2.1.
1. System Status Codes
Thestatusareaisusedtoindicatethecurrentstatusofthe
system.Itindicatesifthesystemisrunninginautomaticor
manualcycle,ifitisturnedonoroffandwhereitisinthe
operatingsequence.
a. START-UP
Indicatesthattheapplianceisinstart-upcycleandisinthe
processoflightinganinitialchargeoffuel.
b. SS-LOW or SS-MED (SS = soft start)
Indicatesthesoft-startportionofthelightingsequence.In
thesestagestherebeginstograduallybuildtooperating
temperature.
c. AUTO: (x) or MAN: (x) (x) = heat output level
Indicates both the operating cycle (automatic or manual)
andthecurrentheatoutputlevel.Theheatoutputlevelwill
be“H”high,“MH”mediumhigh,“M”medium,“ML”medium
lowand“L”low.
d. READY
Indicatesthatthesystemisturnedonandisfunctioningnor-
mally,butthereisnocallforheat(theroomtemperatureis
notbelowthesettemperature).See Figure 7.1 on page 7.
e. SHUTDOWN
Indicatesthesystemisshuttingdown,eitherbecauseitisno
longercallingforheatorthemaximumburntimehasbeen
reachedandthesystemmustrunanauto-cleancycle.
f. AUTO-CLEAN
Indicatesthesystemisrunningtherepotauto-cleancycle.
g. OFF
Indicatesthesystemhasbeenshutdownbytheuser.
h. MAINT BURN (Battery Back-up Only)
Themaintenanceburnistokeepthesystemfromshutting
downwhenoperatingonbatterybackup.Theappliancewill
notautomaticallyre-lightinmanualmode.
2. Current Time
Indicatesthecurrenttime.Thetimeisusedfortheprogram-
mablesetbackfeaturesofthewallcontrol.
3. Set Temperature
Indicates the current set temperature. It will change auto-
maticallyasthe control progresses throughthe7 day set-
backprogram.IfthewallcontrolisinHOLDTEMPcyclethe
“Setat:”indicationwillchangeto“Holdat:”anddisplaysthe
operatingtemperaturesetting.
4. Notication Icons
Thesystemnoticationareausesiconstoindicateifanac-
tionneedstobetaken.Inbatterymodeitindicatestheap-
proximatechargelevelofthebattery.
HopperLidOpen
DoorOpen LowFuel
FullyCharged 2/3Charge
1/3Charge
NoCharge
OperatingonOptionalBatteryBackup