Owner`s manual
R
January 17, 2007
7036-135B
Page 15
Mt. Vernon Pellet Insert (AE)
C. Full Reline With Outside Air
Figure 15.1
Outside Air
Termination
at
Chimney Top
Outside Air
through
Rear Wall
12” (305mm)
min. below
12” (305mm)
min. above
NOTE; Use metal
plate around
exhaust vent pipe
and seal all edges
with non-flammable
insulation such as
fiberglass, mineral
wool or ceramic.
Do not use high
temperature caulk-
ing materials to
seal any edge to
prevent furture
serviceability.
NOTE: Check clearances carefully for this type of instal-
lation to ensure adequate room for outside air venting.
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fi re offi cials or authorities having
jurisdiction about restrictions, installation inspection, and
permits.
CAUTION
NOTE: In Canada only a full reline is allowed per ULC
S628, ORD ULC C1482.