Owner`s manual

Page 14
7036-135B
January 17, 2007
R
Mt. Vernon Pellet Insert (AE)
5
Venting Systems
Figure 14.2
A. Direct Connect Without Outside Air
B. Direct Connect With Outside Air
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.
OutsideAir
through
Rear Wall
Figure 14.1
Fire Hazard
Inspection of Chimney:
Masonry chimney must be in good condition.
Meets minimum standard of NFPA 211
Factory-built chimney must be 6 inch (152mm)
UL103 HT.
WARNING
CAUTION
Never draw outside combustion air from:
• Wall, oor or ceiling cavity
Enclosed space such as an attic or garage
NOTE:
Illustrations re ect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
NOTE; Use metal plate
around exhaust vent pipe
and seal all edges with
non- ammable insulation
such as berglass, mineral
wool or ceramic material.
Do not use high tempera-
ture caulking materials to
seal any edge to prevent
future serviceability.