With proper installation, operation, and maintenance your appliance will provide years of trouble-free service. If you do experience a prob-
lem, this troubleshooting guide will assist a quali ed service person in the diagnosis of a problem and the corrective action to be taken.
This troubleshooting guide can only be used by a quali ed service technician.
Error Message
Possible Cause Corrective Action
Bad wall control or control board
3 wires have loose connections or installed wrong
Replace wall control or control board
Check connections
BAD TC DROP TUBE
(TC = Thermocouple)
Drop tube thermocouple is broken or leads are
reversed
Check connections
Replace thermocouple
BAD TC FIREPOT
(TC = Thermocouple)
Firepot thermocouple is broken or leads are reversed Check connections
Replace thermocouple
SNAP DISC TRIPPED Overheat sensor (snap disc) has tripped
Convection blower may need cleaning
Turn power off to appliance and manually reset snap
disc then turn power back on
Clean convection blower if needed
VACUUM SW ERROR
(SW = Switch)
Vacuum switch is bad
Vacuum hose is plugged/disconnected
Check connections. Bypass vacuum with jumper
wire, if runs, switch is bad. Replace switch
Check vacuum hose
COMB BLOWER JAMMED Combustion blower is blocked/jammed Remove blockage
Replace blower if necessary
Must unplug appliance to clear error
AUGER JAMMED Auger jammed, feed motor bad Pull the feed system and inspect
Clear jam and Press Retry
MISSED IGNITION Igniter bad or poor harness connection
Out of fuel or fuel is bridging in hopper
Faulty repot thermocouple connection has shorted.
Ash plugging the igniter slot in the repot bottom and
clear the slot
Check connections, if OK replace igniter
Break up bridging pellets. Re ll hopper
Replace the thermocouple
Press Retry
Use cleaning tool or a spoon to scrape ash
MIN FIREPOT TEMP Out of fuel Re ll hopper
Add handful of pellets to repot to prime it
Press Retry
MAX DROP TUBE TEMP Appliance in over-heat condition
Flame height set too high
Components may need cleaning
Con rm setting matches burning fuel
Adjust ame height
Clean the rebox, heat exchanger, convection
blower, repot and ash pan
CONV BLOWER JAMMED Convection blower blocked/jammed Remove blockage
Replace blower if necessary
Must unplug appliance to clear error
CHECK ASHPAN Auto-clean jammed
Auto-clean switch is bad
Linkage has become disconnected
If ashpan is empty, check for a jam. Use a screw
driver and rmly push in the repot oor holes and
ex spring and push toward home to release jam
Replace switch
Reconnect linkage
SCREEN GOES BLANK Static discharge or nearby lightning or
Electric fast transients at the input mains
Wait 25 seconds and press any key to refresh the
screen.
Hopper lid not closed all the way
Switch is out of adjustment (auger will not function)
Close the lid. If that didn’t work replace the switch
Adjust or replace switch
Firebox door is not latched properly Adjust or replace door switch
Out of fuel Check the fuel level, if OK the switch may be out,
replace switch
5 Troubleshooting Guide