C. Gas Connection
Note: Have the gas supply line installed in accordance
with local building codes, if any. If not, follow ANSI
223.1.Installationshouldbe donebyaqualiedinstaller
approvedand/orlicensed as required by the locality.(In
theCommonwealthofMassachusettsinstallationmustbe
performedbyalicensedplumberorgastter.)
Note: A listed (and Commonwealth of Massachusetts
approved)1/2in.(13mm)T-handlemanualshut-offvalve
and exible gas connector are connected to the 1/2 in.
(13mm)controlvalveinlet.
If substituting for these components, please consult
local codes for compliance.
WARNING
Fire Risk
Explosion Risk
• Gas build-up during line purge may
ignite.
• Purgeshouldbeperformedbyqualied
technician.
• Ensureadequateventilation.
Ensure there are no ignition sources such
assparksoropenames.
• Incoming gas line should be piped to the 1/2 in.
connection.
• Theapplianceanditsindividualshutoffvalvemustbe
disconnectedfromthegassupplypipingsystemduring
anypressuretestingofthatsystemattestpressures
inexcessof1/2psi(3.5kPa).
• Asmallamountofairwillbeinthegassupplylines.
Whenrstlightingapplianceitwilltakeashorttime
forairtopurgefromlines.Subsequentlightingofthe
logsetwillnotrequiresuchpurging.
WARNING
CHECK FOR GAS LEAKS
Fire Risk
Explosion Risk
Asphyxiation Risk
• Checkallttingsandconnections.
• Donotuseopename.
• Afterthegaslineinstallationiscomplete,
all connectionsmust betightenedand
checked for leaks with a commercially
available, non-corrosive leak check
solution.Besuretorinseoffallleakcheck
solutionfollowingtesting.
Fittingsandconnectionsmayhaveloosened
duringshippingandhandling.
D. High Altitude Installations
OMNIgasappliancesaretestedandapprovedwithoutre-
quiringchangesforelevationsfrom0to2000ftintheUSA
andCanada.
Wheninstallingthisapplianceatanelevationabove2000ft,
itmaybenecessarytodecreasetheinputratingbychang-
ing the existing burner orice to a smaller size. Input rate
shouldbereducedby4%foreach1000ftabovea2000ft
elevationintheU.S.A.,or10%forelevationsbetween2000
and4500ftinCanada.Iftheheatingvalueofthegashas
beenreduced,theserulesdonotapply.Toidentifytheprop-
eroricesize,checkwiththelocalgasutility.
Ifinstallingthisapplianceatanelevationabove4500ft(in
Canada),checkwithlocalauthorities.