Installation manual

8 7061-197D November 7, 2014
Explorer II Medium Wood Stove
B. Clearances to Combustibles
BACKWALL / SIDEWALL
A
B
C
C
CORNER INSTALLATION
B
ALCOVE TOP VIEW
D
A
ALCOVE SIDE VIEW
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
Fire Risk.
Comply with all minimum clearances to
combustibles as speci ed.
Failure to comply may cause house re.
WARNING
A B C D
INSTALLATION: FULL VERTICAL OR ALCOVE
SINGLE WALL PIPE
DOUBLE WALL PIPE
Explorer II 9.38 (238) 20.25 (514) 10.5 (267) 55 (1397)
* FOLLOW PIPE MANUFACTURES CLEARANCES AS REQUIRED
Explorer II 10.5 (267) 20.25 (514) 13.5 (343) 55 (1397)
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches & (Millimeters)
NOTE: All A, B, and C Dimensions are to the center of the ue collar
For alcove only: Six inch diameter listed Double wall air insulated connector
pipe with UL103 HT listed factory built Class A chimney or masonry chimney.
Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a
minimum height of 48 inches (1220mm) to top of unit and the referenced
clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory
built chimney
D
STOVE TO CEILING
CLEARANCE
*
12
(305)
20.25
(514)
50
(1270)
MANTEL
12” MAX
HORIZONTAL THROUGH WALL
TOP AND SIDE VIEW