Owner`s manual

Page 7Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11
3
Appliance Location and Clearances

NOTE:
· Illustrations refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
· Illustrations/diagrams are not drawn to scale.
· Actual installation may vary due to individual design
preference.
When selecting a location for your appliance it is important to
consider the required clearances to walls (see ).

Fire Risk
Provide adequate clearance:
Around air openings
To combustibles
For service access
Locate appliance away from traffi c areas.
Fire Risk.
Locate and install appliance to all
clearance specifi cations in manual.



Model A A* B C D E F G H I
Columbia Bay FS
Inches
6 6-3/4 2 6 14 2 84 19 36 36
Millimeters
152 171 515 152 356 51 2134 483 914 914
NOTE: Flooring beneath appliance may reach 90 degrees
plus room ambient temperature. Check with flooring
manufacturer for maximum temperature allowed on flooring
surfaces.
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the
appliance causing discoloration or odor.
Fire Risk.
Odor Risk.
Tipping Risk
Install appliance on a stable, level platform/
oor strong enough to support appliance
without tipping.
USE wood fl ooring, ceramic tile, brick hearth
or high pressure laminate fl ooring applied
directly over the sub-fl ooring material.

A
B
C
A*
A*
E
D
H
E
F
I
G - Alcove Height
    
