Owner`s manual

Page 38
Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11
11

Although the frequency of your appliance servicing and
maintenance will depend on use and the type of installation,
a qualifi ed service technician should perform an appliance
check-up at the beginning of each heating season.
Risk of injury or property damage.

Turn off gas.
Turn off electricity to appliance.
Ensure appliance is completely cooled.

Replace front and glass, if removed.
Reseal and reinstall any venting removed for servicing.

Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours
operation. 


CAUTION

Avoid striking, scratching or slamming glass.
Do NOT use abrasive cleaners.
Use a hard water deposit glass cleaner on white fi lm.
Do NOT clean glass when hot.
Turn off appliance after 3-4 hours of operation and ALLOW
TO COOL.
Remove and clean glass assembly.
Replace glass assembly and operate appliance for additional
12 hours.
Refer to maintenance instructions.
Inspect external vent cap regularly.
Ensure no debris blocks cap.
Combustible materials blocking cap may
ignite.
Restricted air fl ow affects burner operation.


Annual inspection by qualifi ed technician recommended.

Condition of glass, glass assembly and glass seal.
Obstructions of combustion and ventilation air.
Obstructions of termination cap.
Burner ignition and operation.
Burner air shutter adjustment
Gas connections and fi ttings.
Clean:
Glass
Air passageways, grilles,
control compartment
Burner, burner ports. 


Fire
Delayed ignition or explosion
Exposure to combustion fumes
Odors