Quadra-Fire • COLBAY-FS-B • 250-5195 Rev. R • 10/11
11
Although the frequency of your appliance servicing and
maintenance will depend on use and the type of installation,
a qualifi ed service technician should perform an appliance
check-up at the beginning of each heating season.
Risk of injury or property damage.
• Turn off gas.
• Turn off electricity to appliance.
• Ensure appliance is completely cooled.
• Replace front and glass, if removed.
• Reseal and reinstall any venting removed for servicing.
Handle glass assembly with care.
NOTE: Clean glass after initial 3-4 hours
operation.
fi
CAUTION
• Avoid striking, scratching or slamming glass.
• Do NOT use abrasive cleaners.
• Use a hard water deposit glass cleaner on white fi lm.
• Do NOT clean glass when hot.
• Turn off appliance after 3-4 hours of operation and ALLOW
TO COOL.
• Remove and clean glass assembly.
• Replace glass assembly and operate appliance for additional
12 hours.
Refer to maintenance instructions.
Inspect external vent cap regularly.
• Ensure no debris blocks cap.
• Combustible materials blocking cap may
ignite.
• Restricted air fl ow affects burner operation.
Annual inspection by qualifi ed technician recommended.
• Condition of glass, glass assembly and glass seal.
• Obstructions of combustion and ventilation air.
• Obstructions of termination cap.
• Burner ignition and operation.
• Burner air shutter adjustment
• Gas connections and fi ttings.
Clean:
• Glass
• Air passageways, grilles,
control compartment
• Burner, burner ports.
• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors