6 7034-276 January 29, 2014
MT. VERNON AE
EPACertied: 4.16 grams per hour
Efciency: 81.4% - 83.6%
EPA BTU Output: 14,620-52,460/hr
Heating Capacity: 2,400 - 3,800 square feet
depending on climate zone
Vent Size: 3” or 4” Type “L” or “PL”
Fuels: Pellets, Shelled Field Corn,
WheatandBlackSunower
Seeds
Shipping Weight: 429lbs
*BTUwillvary,dependingonthetypeoffuelyouuseinyour
appliance.ConsultyourQuadra-Firedealerforbestresults.
C.GlassSpecications
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
D. Electrical Rating
115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps
Model Mt.VernonPelletStove
Laboratory OMNITestLaboratories,Inc.
Report No. 061-S-68-6
Type SolidFuelRoomHeater/PelletFuel
BurningType
Standard ASTME1509-04,ULCS627-00and
ULC/ORD-C1482-M1990RoomHeater
PelletFuelBurningtypeand(UM)
84-HUD,MobileHomeApproved.
FCC Complies with Part 15 of FCC Rules.
Operationissubjecttothefollowing
twoconditions:(1)thisdevicemaynot
causeharmfulinterference,and(2)this
device must accept any interference
received, including interference that may
cause undesired operation.
• Installationanduseofanydamagedappliance.
• Modicationoftheappliance.
Installation other than as instructed by Hearth & Home
Technologies.
• Installationand/oruseofanycomponentpartnotapprovedby
Hearth&HomeTechnologies.
• Operatingappliancewithoutfullyassemblingallcomponents.
• Operatingappliancewithoutlegsattached(ifsuppliedwithunit).
• DoNOTOverre-Ifapplianceorchimneyconnectorglows,
youareoverring.
Anysuchactionthatmaycausearehazard.
1 Listing and Code Approvals
A.ApplianceCertication
NOTE:Hearth&HomeTechnologies,manufacturerof
this appliance, reserves the right to alter its products, their
specicationsand/orpricewithoutnotice.
NOTICE: This installation must conform with local codes. In
theabsenceoflocalcodesyoumustcomplywiththeASTM
E1509-04, ULC S627-00, (UM) 84-HUD and ULC/ORD-
C-1482.
Improper installation, adjustment, alteration, service or
maintenancecancauseinjuryorpropertydamage.
Forassistanceoradditionalinformation,consultaqualied
installer, service agency or your dealer.
Quadra-FireisaregisteredtrademarkofHearth&Home
Technologies.
WARNING
FireRisk.
Hearth&HomeTechnologiesdisclaimsany
responsibilityfor,andthewarrantywillbe
voidedby,thefollowingactions:
B.BTU&EfciencySpecications
E. Mobile Home Approved
• Thisapplianceisapprovedformobilehomeinstalla-
tions when not installed in a sleeping room and when
anoutsidecombustionairinletisprovided.
• Thestructuralintegrityofthemobilehomeoor,ceil-
ing,andwallsmustbemaintained.
• The appliance must be properly grounded to the
frameofthemobilehomeanduseonlyListedpellet
vent Class “L” or “PL” connector pipe.
• OutsideAirKit,partOAK-ACCmustbeinstalledina
mobilehomeinstallation.