Owner`s manual

20 7034-276 January 29, 2014
MT. VERNON AE
H. Error Codes
If a system error occurs that forces the system to stop op-
erating an error screen appears. Depending upon the error
type, up to three retry attempts are allowed after which a
service professional is required.
Press the ERROR LIST button to display the latest error.
See page 30 for a list of error codes.
G. Service Information
The SERVICE INFORMATION screen displays contact in-
formationfor Hearth & HomeTechnologiesCustomerSer-
vice Line. The local dealer may have changed this upon or
beforetheinstallationtoindicateadealerhotline.
www.quadrafire.com
to locate your nearest
dealer
DONE
ERROR LIST
Figure 20.2
MANUAL LIGHT PROCEDURE
Press “CONTINUE”
button to start manual
lighting sequence
Current Tem: 72 F
O
CONTINUE
MANUAL LIGHT PROCEDURE
Please wait while
feed charge is loading
into firepot
MANUAL LIGHT PROCEDURE
Open door...
Manually light fuel...
Close door
Figure 20.1
13 Volts
12 Volts 11 Volts
Battery
Below
10 Volts
Refer to page ___forinstructionsonhowtoattachthecable
to appliance. The following are screens you will see when
usingaback-upbattery.
OperatingonBatteryBack-Up
• Abatteryiconappearsonyourwallcontroltoletyouknow
youarenowoperatingonbatterypower.Figure 20.3.
• Firemustbemanuallylitastheappliancewillnolonger
automatically light. See section G on page 9.
• Useonlyapprovedrestartinggeltostartre.
• Highburnrateisnolongeravailableonbatteryback-up.
• Each level drops down one level, i.e the high burn be-
comesmedium-highburnandsoon.
• Ifthebatterychargefallsbelow10voltitcannolonger
sustain the appliance operation and the appliance will
shutdown.Youmustdisconnectandreconnectthebat-
tery to start it up again.
RecommendedBattery
• 12voltdeepcyclebattery,(i.e.,marineorRVtype).
• A 12 volt battery cable is available through your local
dealer.
WARNING! Risk of Injury!
• Blowersmaycontinuetorunandwouldbeexposedto
human contact.
Figure 20.3
MAINT BURN
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
“Maint Burn” will display when
the thermostat has reached the
set room temperature and will
run on low until it reaches its
auto-clean cycle time.
Battery icon.
Figure 20.4
Wall Control Display
Thewallcontrolwilldisplaythebatteryiconwhenoperating
inthebatteryback-upmode.Figure 20.4.
I. Battery Back-up System (Optional)
CAUTION!
• HookuptobatteryterminalsBEFOREyouplugbattery
into appliance.
• Damagetointernalelectroniccomponentsmayoccur.
Theappliancehasbeendesignedtooperateonanoptional
batteryback-upsystem.
If you have frequent power outages in your region, hook
theapplianceuptoa12voltbatteryanditwillautomatically
switchtobatterypowerintheeventofapowerfailure.The
12 volt power cord sold as a separate accessory does not
chargethebattery.