Owner`s manual
January 29, 2014 7034-276 17
MT. VERNON AE
b. Flame Height Adjust
FLAMEHEIGHTADJUSTisusedtoadjustameheight(fuel
feedrate)forspecicinstallationandfueltype.Thedealer
will usually adjust this ifnecessary on installation and can
adviseonspecicsettingsforaparticularapplication.
Figure 17.1
d. Temperature Calibration
TEMPERATURE CAL is used to calibrate the tempera-
ture on the wall control. If for some reason you feel the
wall control is not accurately reading the temperature you
cancalibrateittoathermostatthatyouknowisaccurate.
PresstheUP/DOWNbuttonstodesiredtemperature.
c. Temp Differential
TEMPERATURE DIFFERENTIAL is used to change the
setdefaulttemperaturedifferential.Thissetshowfarbe-
low the set point the wall control allows the room tempera-
turetofallbeforetheapplianceturnsbackon.Itisusually
set at time of installation.
Figure 17.2
TEMPERATURE CAL
71.6
O
F
Cal Adj:
-13
DONE SET
Figure 17.3
e. Properties
PROPERTIESshowstheversionofsoftwareforthecontrol
boardandwallcontrol.Ifyouareplacingaservicecallwith
yourdealer,theymayaskyoutogotothisscreenandread
them the information under “WC” and “SC”.
WC
SC
CB
CV
40h
6Bh
000
000
UFTI: 029
Rev: 004
TC: -28
PROPERTIES
DONE
Figure 17.4
f. Elevation
ELEVATION allows you to adjust the appliance to your
specicelevation.PresstheUP/DOWNbuttonstoselect
your elevation. The message in the center will change
betweenNORMALandHIGH.IfyouselectHIGH,itwill
replace the normal fuel tables with specic high fuel ta-
bles.YouMUST select a fuel type after selecting HIGH.
Please note that changing the elevation will delete any
customornewfueltableloadedintotheappliance.You
mustconrmyourchoiceontheCONFIRMELEVATION
CHANGE screen. This allows you to reverse your deci-
sion if necessary. Figure 17.6
ELEVATION
Over 4000 FT
Normal / High
Up to 4000 FT
DONE
Figure 17.5
CONFIRM ELEVATION CHANGE
YES
Changing elevations will
delete any custom or
new fuel tables loaded into
the stove.
Are you sure?
NO
Figure 17.6
g. Convection Blower Speed
CONVBLOWERSPEEDallowsyoutoadjusttheblower
speedtoyourindividualpreference.PresstheUP/DOWN
buttonstoselectyourblowerspeed.Themessageinthe
centerwillchangebetweenNORMALandQUIET.
NORMALallowstheconvectionblowertoreachmaximum
RPMat135degreesandQUIETat165degrees.
CONV BLOWER SPEED
Normal
Normal / Quiet
Quiet
DONE
Figure 17.7
h. Language Selection
LANGUAGE allows you to select from four different lan-
guages. To select a language scroll down to the last item
ontheUSERSETTINGscreenusingtheDOWNbutton.
Using the UP/DOWN buttons select the preferred lan-
guage and then press Select and then press Done.
LANGUAGE
SELECT
DONE
Français
Norvégien
Suédois
Anglais
Figure 17.8