A. Introduction
Welcome to the Quadra-Fire family. This manual will help
you understand and operate the wall control attached to
your new pellet appliance.
TheQuadra-Fire WallControl is not just a traditionalther-
mostat,butanintegralpartofthepelletappliancesystem.
While it has many of the features one would expect from
an advanced thermostat, including programmable setback
capabilitiesandcurrenttemperaturedisplay,italsoindicates
thesystem’scurrentoperatingcycleandstate.Itdoesthis
bycommunicatingwiththeapplianceviaawiredconnection.
Additionally, it allows you to set parameters that will optimize
the performance of your pellet appliance system. These pa-
rameters are accessed with an easy to navigate menu sys-
tem.
B. Language Selection
The language selection function is under the USER
SETTINGS found on pages 17. Please refer to that
section for complete detailed instructions.
C. The Main Screen
Thekeytobeingcomfortablewhileoperatingyournewwall
control is to familiarize yourself with the main screen. The
main screen shows, at a glance, the status of the system,
the most important settings and the current temperature. Ad-
ditionally, the main screen indicates with simple icons many
useractionsrequiredtokeepyourapplianceworkingasin-
tended. Figure 13.1.
READY
73
Set at: 73
12:30 PM
HEAT OUTPUT
MENU
Current Time
System Status
Current Set
Temperature
Current
Temperature
Function Labels for the Function Buttons
Notifications
Icons
Figure 13.1
Figure 13.2
1. System Status Codes
The status area is used to indicate the current status of the
system. It indicates if the system is running in automatic or
manual cycle, if it is turned on or off and where it is in the
operating sequence.
a. START-UP
Indicates that the appliance is in start-up cycle and is in
the process of lighting an initial charge of fuel.
b. SS-LOW or SS-MED (SS = soft start)
Indicates the soft-start portion of the lighting sequence. In
thesestagestherebeginstograduallybuildtooperating
temperature.
c. AUTO: (x) or MAN: (x) (x) = heat output level
Indicatesboththeoperatingcycle(automaticormanual)
and the current heat output level. The heat output level
willbe“H”high,“MH”mediumhigh,“M”medium,“ML”me-
dium low and “L” low.
d. READY
Indicates that the system is turned on and is functioning
normally,butthereisnocallforheat(theroomtempera-
tureisnotbelowthesettemperature).
e. SHUTDOWN
Indicates the system is shuttingdown, either because it
is no longer calling for heat or the maximum burn time
hasbeenreachedandthesystemmustrunanauto-clean
cycle.
f. AUTO-CLEAN
Indicatesthesystemisrunningtherepotauto-cleancy-
cle.
g. OFF
Indicatesthesystemhasbeenshutdownbytheuser.
h. MAINT BURN (Battery Back-up Only)
Themaintenanceburnistokeepthesystemfromshutting
downwhenoperatingonbatterybackup.Theappliance
willnotautomaticallyre-lightinbatteryback-upmode.
2. Current Time
Indicates the current time. The time is used for the program-
mablesetbackfeaturesofthewallcontrol.
3. Set Temperature
Indicates the current set temperature. It will change auto-
matically as the control progresses through the 7 day set-
backprogram.IfthewallcontrolisinHOLDTEMPcyclethe
13 Volts
12 Volts 11 Volts
Battery
Below
10 Volts
HopperLidOpen
DoorOpen Low Fuel
Fully Charged 2/3Charge
1/3Charge
No Charge
OperatingonOptionalBatteryBackup
3 Wall Control Operating Instructions