4300 Wood Stove Series (ACC)
R
2
Getting Started
A
. Design, Installation & Location Considerations
Considerationmustbegivento:
• Safety
• Convenience
• Trafcow
• Chimneyandchimneyconnectorrequired
Itisagoodideatoplanyourinstallationonpaper,usingexact
measurementsfor clearances and oor protection,before
actuallybeginningtheinstallation.Ifyouarenotusingan
existingchimney,placetheappliancewheretherewillbea
clearpassageforafactory-builtlistedchimneythroughthe
ceilingandroof.
Werecommendthataqualiedbuildinginspectorandyour
insurancecompanyrepresentativereviewyourplansbefore
andafterinstallation
Ifthisapplianceisinanareawherechildrenmaybenearit
isrecommendedthatyoupurchaseadecorativebarriertogo
infrontoftheappliance.
Remembertoalwayskeepchildren
away while it is operating and do not let anyone operate
thisapplianceunlesstheyarefamiliarwiththeseoperating
instructions.
B. Fire Safety
To provide reasonable re safety, the following should be
givenseriousconsideration:
1. Install at least one smoke detector on each oor of
your home to ensure your safety. They should be
located away from the heating appliance and close
to the sleeping areas. Follow the smoke detector
manufacturer’splacementandinstallationinstructions,
andbesuretomaintainregularly.
2. A conveniently located ClassA fire extinguisher
to contend with small fires resulting from burning
embers.
3. Apracticedevacuationplan,consistingofatleasttwo
escaperoutes.
4. Aplantodealwithachimneyreasfollows:
Intheeventofachimneyre:
a. Evacuatethehouseimmediately
b. Notifyredepartment
WARNING
• DONOTCONNECTTHISUNITTOACHIM-
NEYFLUESERVICINGANOTHERAPPLI-
ANCE.
• DONOTCONNECTTOANYAIRDISTRIBU-
TIONDUCTORSYSTEM.
Mayallowuegasestoenterthehouse.
Asphyxiation Risk.
Fire Risk.
WARNING
• Donotoperateappliancebeforereadingand
understandingoperatinginstructions.
• Failuretooperateapplianceproperlymay
causeahousere.
Checkbuildingcodespriortoinstallation.
• Installation MUST comply with local, regional, state and
nationalcodesandregulations.
• Consult insurance carrier, local building, re ofcials or
authoritieshavingjurisdictionaboutrestrictions,installation
inspection,andpermits.
CAUTION
NOTE: Service Space:
In order to replace the tube channel a clearance of 19
inches (483mm) is required on the right side of stove in
ordertoremovethetubeswiththestoveinplace.
Ifspaceisnotavailable,thestovewillhavetobediscon-
nectedfromthechimneytoproceedwiththetubereplace-
ment.See page 36.