Owner`s manual
Page20
7037-135H
December 16, 2011
R
4300 Wood Stove Series (ACC)
6
Mobile Home Installation
10. Burn wood only. Other types of fuels may generate
poisonousgases(e.g.,carbonmonoxide).
11. If unit burns poorly while an exhaust blower is on in
home,(i.e.,rangehood),increasecombustionair.
12. InstallationshallbeinaccordancewiththeManufacturers
Home&SafetyStandard(HUD)CFR3280,Part24.
1. AnoutsideairinletmustbeprovidedforcombustionSee
page 14forinstallationinformation.
2. Appliancemustbesecuredtothemobilehomestructure
by bolting the pedestal through hearth pad and into
oor.
3. Appliance must be grounded with #8 solid copper
groundingwireorequivalentandterminatedateachend
withN.E.C.approvedgroundingdevice.
4. AppliancemustbeinstalledwithanapprovedUL103HT
ventilated chimney connector, UL103 HTchimney, and
terminalcapwithsparkarrestor.Neveruseasinglewall
connector(stovepipe)inamobilehomeinstallation.Use
onlydouble-wallconnectorpipe,Dura-VentDVL,Selkirk
metalbestosDSorSecurityDLdouble-wallconnectoror
anylisteddouble-wallconnectorpipe.
5.
InCanada,thisappliancemustbeconnectedtoa6inch
(152mm) factory-built chimney conforming to CAN/ULC-
629M,STANDARDFORFACTORYBUILTCHIMNEYS.
6. Followthechimneyandchimneyconnectormanufacturer’s
instructionswheninstallingtheuesystemforuseina
mobilehome.
7. Maintainclearancetocombustibles.
8. Floor protection requirements must be followed
precisely.
9. Use silicone to create an effective vapor barrier at the
locationwherethechimneyorothercomponentpenetrates
totheexteriorofthestructure.
NOTE: Offsets from the vertical, not exceeding 45°, are
allowedperSection905(a)oftheUniformMechanicalCode
(UMC).Offsetsgreaterthan45°areconsideredhorizontal
andarealsoallowed,providingthehorizontalrundoesnot
exceed75%oftheverticalheightofthevent.Construction,
clearanceandterminationmustbeincompliancewiththe
UMCTable9C.ThisinstallationmustalsocomplywithNFPA
211.
NOTE:Topsectionsofchimneymustberemovabletoallow
maximumclearanceof13.5feet(411cm)fromgroundlevel
fortransportationpurposes.
Figure 20.1
SparkArestorCap
RoofFlashing
StormCollar
JoistShield/Firestop
Doublewall
connectorpipe
FloorProtector
Outside Air Floor Vent
OutsideAir
RearVent
CAUTION
THESTRUCTURALINTEGRITYOFTHEMOBILEHOME
FLOOR,WALLANDCEILING/ROOFMUSTBEMAIN-
TAINED
DoNOTcutthrough:
• Floorjoist,wall,studsorceilingtrusses.
• Anysupportingmaterialthatwouldaffectthestructural
integrity.
NEVERINSTALLINASLEEPINGROOM.
Consumesoxygenintheroom.
WARNING
Asphyxiation Risk.
You must use a Quadra-Fire Outside Air Kit Part
OAK-ACC and (depending on oor installation)
Part SRV7033-041 for installation in a mobile
home.