Owner`s manual

December 16, 2011
7037-135H
Page19
4300 Wood Stove Series (ACC)
R
D. Chimney Termination Requirements
Followmanufacturersinstructionsforclearance,securing,
ashingandterminatingthechimney.
Musthaveanapprovedandlistedcap
Mustnotbelocatedwhereitwillbecomepluggedby
snoworothermaterial
• Mustterminateatleast3feet(91cm)abovetheroof
andatleast2feet(61cm)aboveanyportionofthe
roofwithin10feet(305cm)
• Must be located away from trees or other struc-
tures
These are safety requirements and are not meant to assure proper ue draft.
Figure 19.1
E. 2-10-3 Rule
Figure 19.2
NOTE:
• Chimneyperformancemayvary.
• Trees,buildings,rooflinesandwindconditionsaffect
performance.
• Chimneyheightmayneedadjustmentifsmokingor
overdraftoccurs.
3ft.(91cm)
Minimum
Lessthan10ft.(305cm)
2ft.(61cm)
3ft.(91cm)
Minimum
10ft.(305cm) ToNearestRoofline
2ft.(61cm)
PitchedRoof
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof