Owner`s manual
Page18
7037-135H
December 16, 2011
R
4300 Wood Stove Series (ACC)
Chimney Height / Rise and Run
Thisproductwasdesignedforandtestedona6inch(152mm)
chimney, 14 to 16 feet (420-480cm) high, (includes stove
height)measuredfromthebaseoftheappliance.Thefurther
yourstackheightordiametervariesfromthisconguration,
thepossibilityofperformanceproblemsexists.
Chimneyheightmayneed to be increasedby2
-3%per
each1000feetabovesealevel.Itisnotrecommendedto
useoffsetsorelbowsataltitudesabove4000feetabovesea
levelorwhenthereareotherfactorsthataffectuedraft.
C. Installing Chimney Components
Chimney Connector
Singlewallconnectororstovepipe.
Thismustbeatleast24gaugemildsteelor26gaugeblue
steel.Thesectionsmustbeattachedtotheapplianceandto
eachotherwiththecrimped(male)endpointingtowardthe
stove.Alljoints,includingtheconnectionattheuecollar,
shouldbesecuredwith3sheetmetalscrews.Makesure
tofollowtheminimumclearancestocombustibles.Where
passagethroughthewall,orpartitionofcombustiblecon-
structionisdesiredinCanada,theinstallationshallconform
toCAN/CSA-B365.
Factory-builtlistedchimneyconnector(vented).
Alistedconnector(vented)mustbeusedwheninstallingthis
unitinamobilehome.Thelistedconnectorsmustconform
toeachothertoensureapropertandseal.
FlueGas
Direction
Crimped
End
Toward
Stove
Securepipesectionswitha
minimumof3screws
Figure 18.2 Chimney Connector (Stove Pipe)
Improperinstallation,adjustment,alteration,serviceor
maintenancecancauseinjuryorpropertydamage.Refer
totheowner’sinformationmanualprovidedwiththisappli-
ance.Forassistanceoradditionalinformationconsulta
qualiedinstaller,serviceagencyoryourdealer.
WARNING
Fire Risk.
InspectionofChimney:
• Chimneymustbeingoodcondition.
• MeetsminimumstandardofNFPA211
• Factory-builtchimneymustbe6inch
(152mm)UL103HT.
WARNING
WARNING
ONLYuseconnector:
• Withintheroom,betweenapplianceandceilingorwall.
ConnectorshallNOTpassthrough:
• Atticorroofspace
• Closetorsimilarconcealedspace
• Floororceiling
Maintainminimumclearancestocombustibles
Fire Risk.
FollowChimneyConnectorManufacturer’s
InstructionsforProperInstallation.
ChimneyFlue
Liner
Fireclay
Lineror
Equivalent
MasonryChimney
ConstructedtoNFPA211
WallSpacer
WallBand
TrimCollar
Chimney
Connector
1inch(25mm) Air
SpacetoChimney
Section
Min.Clearance
2inch(51mm)
Min.ChimneyClearanceto
WallSpacerand
Combustibles-2inch(51mm)
ChimneySection
Figure 18.1
Solid Pack Chimney with Metal Supports as a
Thimble (Cont’d)
WARNING
• DONOTCONNECTTHISUNITTOACHIM-
NEYFLUESERVICINGANOTHERAPPLI-
ANCE.
• DONOTCONNECTTOANYAIRDISTRIB-
UTONDUCTORSYSTEM.
Mayallowuegasestoenterthehouse.
Asphyxiation Risk.