Owner`s manual

Page16
7037-135H
December 16, 2011
R
4300 Wood Stove Series (ACC)
NOTE: InCanadawhenusingafactory-builtchimneyitmust
besafetylisted, Type UL103 HT (2100
o
F) CLASS “A” or
conformingtoCAN/ULC-S629M, STANDARD FOR 650
o
C
FACTORY-BUILT CHIMNEYS.
5
Chimney Requirements
Floor
Protector
Chimney
Connector
Insulated"T"
Flashing
Listed Termination Cap
Trim Collar on
InsideWall
ListedChimney
StormCollar
Wall Support
RoofBrace(ifrequired)
Thimble
Floor
Protector
Chimney
Connector
CeilingSupport
ListedChimney
Listed TerminationCap
StormCollar
Flashing
Figure 16.1 Prefabricated Exterior Chimney
Figure 16.2 - Prefabricated Interior Chimney
A. Venting Components
Chimney Connector:
Itis alsoknownasuepipeorstovepipe.Thechimney
connectorjoinsthestovetothechimney.Itmustbea6inch
(152mm)minimumdiameter24gaugemildsteelblackor
26gaugebluedsteel,oranapprovedair-insulateddouble
wallventingpipe.
Thimble:
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet
NFPA 211 Standards. Prefabricated must be suitable
for use with selected chimney and meet UL103Type HT
Standards.Followinstructionsprovidedbythemanufacturer
for manufactured thimbles for masonry chimney and
prefabricatedchimneys.
Chimney:
Thechimneycanbeneworexisting,masonryorprefabricated
andmustmeetthefollowingminimumrequirementsspecied
inSection5B.
B. Chimney Systems
• Must be minimum 6 inch (152mm) diameter (ID) high
temperaturechimney listed toUL103HT(2100
o
F)or
ULCS629M.
• Mustusecomponentsrequiredbythemanufacturerfor
installation.
• Mustmaintainclearancesrequiredbythemanufacturer
forinstallation.
• Refertomanufacturersinstructionsforinstallation.
Prefabricated Metal Chimney