Owner`s manual

Page14
7037-135H
December 16, 2011
R
4300 Wood Stove Series (ACC)
B. Outside Air Kit Installation
1. Removeallmaterialsfrompackingbox.
2. Usinga#2Phillipsscrewdriverattachtheexadapter
tothestoveusing4screws.Figure 14.1.
3. Foroorinstallationsr
emovecircular”knock-out”inthe
baseofthepedestal.
4. Floor & Rear Installation: Cut a 4 inch (102mm)
holeinoutsidewalloroortoaccommodateoutside
airpiping.Use4inch(102mm)aluminummetalexor
rigidpipingtodirectlyconnectoutsideairtoappliance
intake.Usethesuppliedterminationcapwitharodent
screen.Sealbetweenthewall(oroor)andthepipe
withsiliconetopreventmoisturepenetration.
Items Needed for Installation (not supplied)
• 4inchexaluminumpipe,orifusingalternatematerial,
thenitshallbemadefromdurable,non-combustible,
heatresistantmaterialupto350
o
F.Cutthepipeto
therequiredlengthforyourinstallation.
•Phillipsheadscrewdriver
•Siliconesealant
•Drillsandsawsnecessaryfor cuttingholesthrough
thewallorooringinyourhome.
Figure 14.1 - Floor & Rear Installation
Asourceofair(oxygen)isnecessaryinorderforcombus-
tiontotakeplace.Whatevercombustionairisconsumed
bytheremustbereplaced.Airisreplacedviaairleak-
agearoundwindowsandunderdoors.Inhomesthathave
tightlysealeddoorsandwindows,anoutsideairsourceis
needed.AnoptionalOutsideAirKitisavail
able.
Flex Line
Wire Tie
Wire Tie
Flex Adapter
Termination
Cap
For Floor Installa-
tions Remove
Circular “Knock-Out”
in Base of Pedestal.
WARNING
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsor
chimneys
Fumesorodormayresult
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outsideairinletmustbelocatedtopreventblock-
agefrom:
• Leaves
• Snoworice
• Otherdebris
Blockmaycausecombustionairstarvation
Smokespillagemaysetoffalarmsorirritatesensi-
tiveindividuals.
WARNING
Asphyxiation Risk.
LengthofoutsideairsupplyductshallNOTexceed
thelengthoftheverticalheightoftheexhaustue.
Firewillnotburnproperly
Smokespillageoccurswhendoorisopeneddue
toairstarvation.
WARNING
Included in OAK-ACC: Termination cap, (2) wire ties, flex
adapter,andfasteners
Included in SRV7033-041:Coverplateandsealingrope(see
FloorInstallationAlternativebelow,
Figure 14.2)
Figure 14.2 - Floor Installation Alternative
Cover
Plate
RopetoSeal
Pedestal
5.
Floor Installation Alternative: Insomeinstancesyoumay
notbeabletoinstalltheexpipeasshowinFigure 14.1.
If that is thecase, you willneed to order SRV7033-041
whichincludesacoverplateandsealingropeasshownin
Figure 14.2.Thegoalistosealthepedestalsonoroom
aircanleakintothepedestalorcoldairinltration.