Operating instructions
4300 ACT Wood Stove Series
Page 6 250-7061C December 10, 2004
R
DIMENSIONS 
4300 MILLENNIUM MODEL
C
L
21.0" (533mm)
14-15/16"
(379mm)
10-15/16"
(278mm)
10-3/16" 
(259mm)
18.0"(457mm)
25-1/2" (648mm)
12-3/4" 
(324mm)
9-1/2" 
(241mm)
19-1/16" (484mm)
15-1/16" (383mm)
31-1/8" 
(791mm)
C
L
24-11/16" (628mm)
Back of Stove to Glass
C
L
28-1/2" (724mm)
25-1/2" (648mm)
5-1/2" (140mm)
2-1/4" (57mm)
16.0" 
(406mm)
4-3/8" (111mm)
20-3/8" (518mm)
LOCATING YOUR STOVE
WHEN LOCATING YOUR STOVE consider safety, convenience, traffic flow, and the fact that the stove will need a chimney 
and chimney connector. It is a good idea to plan your installation on paper, using exact measurements for clearances and 
floor protection, before actually beginning the installation.  If you’re not using an existing chimney, place the stove where 
there will be a clear passage for a factory-built listed chimney through the ceiling and roof. 
AVOID FIRE:  Maintain the designated clearances to combustibles.  Insulation must not touch the chimney.  You must maintain 
the designated air space clearance around the chimney. This space around a chimney is necessary to allow natural heat 
removal from the area.  Insulation in this space will cause a heat buildup, which may ignite wood framing.  NOTE:  Clearances 
may only be reduced by means approved by the regulatory authority having jurisdiction.
WE  RECOMMEND
  that  a  qualified  building  inspector  and  your  insurance  company  representative  review  your 
plans before and after installation.
VENT SPECIFICATIONS
Single Wall: Six inch (6”) (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built 
chimney type UL103 HT* suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
Double  Wall/Mobile  Home:  Six  inch  (6”)    (152mm)  diameter,  listed  double  wall  air  insulated  connector  pipe  with 
listed factory-built UL103  HT*  Class  “A” chimney, or a masonry chimney  (Mobile  Home must be  equipped  with  a spark 
arrestor),  and  the  referenced  clearances.    Use  only  double-wall  connector  pipe,  Dura-Vent  DVL,  Selkirk  metalbestos 
DS or Security DL double wall connector.
*In Canada must comply with CAN/ULC-S269 for the 650°
Factory-built chimney.