Owner`s manual
Page 14
7075-166B
January 10, 2013
R
VOYAGEUR GRAND Wood Insert
O. Blower Operating Instructions
1. Initial (cold) startup: Openbothcontrolsfullybyrais-
ingtheBurnRateAirControlallthewayupuntilitstops
and PUSH the Start-upAir Control back until it stops.
Theblowertendstocooltheappliance.Leavetheblower
off until the burn is well established, i.e., 30 minutes.
2. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled upand theStart-upAirControl is
fully pushed in. Blower may remain on.
3. Medium-High Burn Setting*: Burn Rate Air Control
is closed then opened to 1 inch to fully open (pull up).
Blower may remain on.
4. Medium-Low Burn Setting*: Burn Rate Air Control
isclosedthenopenedto1/4inchto1/2inch(pullup).
Leave the blower off until the burn is well established, i.e.,
30 minutes.
5. Low Burn Setting*: Burn RateAir Control is closed
(down position).
Leave the blower off until the burn is
well established, i.e., 30 minutes.
*NOTE:Forburnsettings3to5theStart-upAirControl
needs to be pushed in (Open) then pulled forward to
activatetheAutomaticCombustionControl(ACC).
NOTE: Formaximumefciencyandlowestemissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes.
6. Theblowerisequippedwitharheostat(speedcontrol).
The highest blower speed is obtained by turning the
rheostaton, then adjustingback towards“OFF”as far
as possible without turning the blower off. For a low
blowerspeed,turnthecontrolknobclockwiseasfaras
possible
Blower Controls Under Ash Lip
MANUAL: over-
rides the internal
snap disc
AUTO: Fan with turn ON/OFF
automatically and is controlled
by the internal Snap Disc
1. The blower will turn on/off automatically when set to
AUTO.Figure 14.1.
2. WhensettoMANUAL,thefanwillturnon/offonlywhen
youturnitonoroff.Thissettingover-ridestheinternal
snap disc.
3. Swing the grille downward to expose the blower con-
trols.AdjustthespeedofthefanbyturningtheHIGH/
LOWknobtothedesiredsetting.
N. Blower Control Box & Snap Disc
Operating Instructions
Figure 15.1
NOTICE!
DoNOToperateacirculatingfanwithincloseproxim-
ity, approximately 4 ft (1.2m), of appliance
•Canreverseairow,blowinghotairintoappliance
cavity.
•Candamageapplianceblowerduetooverheating.