Specifications
EVAL-ADM1186
Rev. 0 | Page 7 of 24
Table 5. Test Point Functions
Reference Function
5V0B Monitors the voltage at the 5 V regulator output or input to J1-1 depending on position of Switch S1
3V3B Monitors the voltage at the output of the 3.3 V ADM1186 regulator
3_3V Monitors the voltage at the output of the 3.3 V variable regulator
2_5V Monitors the voltage at the output of the 2.5 V variable regulator
1_8V Monitors the voltage at the output of the 1.8 V variable regulator
1_5V Monitors the voltage at the output of the 1.5 V variable regulator
VIN1 Monitors the voltage at the VIN1 pin
VIN2 Monitors the voltage at the VIN2 pin
VIN3 Monitors the voltage at the VIN3 pin
VIN4 Monitors the voltage at the VIN4 pin
UP Monitors the voltage at the UP pin (EVAL-ADM1186-1EBZ only)
/DOWN
Monitors the voltage at the DOWN
pin (EVAL-ADM1186-1EBZ only)
UP/DOWN
Monitors the voltage at the UP/DOWN
pin (EVAL-ADM1186-2EBZ only)
OUT1 Monitors the voltage at the OUT1 pin
OUT2 Monitors the voltage at the OUT2 pin
OUT3 Monitors the voltage at the OUT3 pin
OUT4 Monitors the voltage at the OUT4 pin
PWRGD Monitors the voltage at the PWRGD pin
SEQ_DONE Monitors the voltage at the SEQ_DONE pin (EVAL-ADM1186-1EBZ only)
/FAULT
Monitors the voltage at the FAULT pin (EVAL-ADM1186-1EBZ only)
DLY1 Monitors the voltage at the DLY_EN_OUT1 pin (EVAL-ADM1186-1EBZ only)
DLY2 Monitors the voltage at the DLY_EN_OUT2 pin
DLY3 Monitors the voltage at the DLY_EN_OUT3 pin
DLY4 Monitors the voltage at the DLY_EN_OUT4 pin
BLNK Monitors the voltage at the BLANK_DLY pin
SEQ_DONE_NEXT Monitors the voltage at the SEQ_DONE pin of the next ADM1186-1 device in cascade (EVAL-ADM1186-1EBZ only)
SEQ_DONE_PREV Monitors the voltage at the SEQ_DONE pin of the previous ADM1186-1 device in cascade (EVAL-ADM1186-1EBZ only)
SEQ_CNTRL_A Monitors the voltage on the sequence control bus in cascade (EVAL-ADM1186-1EBZ only)
SEQ_CNTRL_B Monitors the same voltage as SEQ_CNTRL_A (EVAL-ADM1186-1EBZ only)
GND1 Ground terminal
GND2 Ground terminal