Specifications
QSSC-S4R Technical Product Specification BIOS Error Handling
247
Table 170. POST Error Beep Codes
Bee
p
s Error Messa
g
e POST Pro
g
ress Code Descri
p
tion
3 Memory error multiple System halted when a fatal error related to the memory
was detected and system does not have available
memory.
3 Memory Test Error 0xEB The system generates a Memory Error beep code and
then continues to boot if System has available
memory.
3 Channel Training
Error
0xEA The system generates a Memory Error beep code and
then continues to boot if System has available
memory.
21.3.5 POST Error Pause Option
In case of POST error(s) that are listed as Major, the BIOS enters the error manager and waits for the user to press an
appropriate key before booting the OS or entering the BIOS Setup.
The user can override this option by setting the POST Error Pause option as disabled on the BIOS setup Main screen.
If this option is disabled, the system boots the OS without user intervention. The default is disabled.