Product guide
QSSC-S4R Server System Product Guide Chapter 4: Serviceable Components
Version 1.0
65
Note: Pressing the attention button again while the attention LED is flashing cancels the operation.
Figure 53. Pressing the memory riser attention button
3. Press the left and right green latches on the memory bracket downward to release the memory bracket
levers. See letter “B” in the following figure.
4. Rotate the levers upward to disengage the memory riser from the main board. See letter “C” in the following
figure.
Figure 54. Releasing a memory riser
5. Lift the memory riser by the levers of the memory bracket to pull it from the server as shown in Figure 55.
6. Ensure the fan zone airflow configuration is correct, install or remove a memory air baffle if necessary. For
instructions, see “Installing and Removing Memory Air Baffles” on page 67.