Product guide

Chapter 3: Server Utilities QSSC-S4R Server System Product Guide
Version 1.0
48
The following tasks demonstrate some of the features of the Command Line Interface utility. You can monitor
system information, retrieve and save the system event log and start a SOL session.
1. To read the temperature sensors of the remote managed system, type:
dpccli> sensors ¡Vv ¡VT temp
11/14/2008 | 13:58:32 | Baseboard Temp | ok | 28.00 | Celsius
11/14/2008 | 13:58:32 | P1 Mem Margin | ok | 1.00 | Celsius
11/14/2008 | 13:58:32 | IOH Therm Margin | ok | -28.00 | Celsius
11/14/2008 | 13:58:33 | P2 Mem Margin | ok | 0.00 | Celsius
11/14/2008 | 13:58:33 | P1 Therm Margin | ok | -64.00 | Celsius
11/14/2008 | 13:58:33 | P2 Therm Margin | ok | -61.00 | Celsius
2. To read the fan speeds of the remote managed system, type:
dpccli> sensors ¡Vv ¡VT fan
11/14/2008 | 13:59:09 | Processor 1 Fan | ok | 6120.00 | RPM
11/14/2008 | 13:59:09 | Processor 2 Fan | ok | 6120.00 | RPM
11/14/2008 | 13:59:09 | Memory 1 Fan | ok | 0.00 | RPM
11/14/2008 | 13:59:09 | Memory 2 Fan | ok | 4152.00 | RPM
11/14/2008 | 13:59:09 | System 1 Fan | ok | 0.00 | RPM
11/14/2008 | 13:59:09 | System 2 Fan | ok | 2688.00 | RPM
11/14/2008 | 13:59:09 | System 3 Fan | ok | 0.00 | RPM
11/14/2008 | 13:59:09 | System 4 Fan | ok | 2832.00 | RPM
dpccli>
3. To read all system sensors, type:
dpccli> sensors ¡Vv
11/14/2008 | 13:58:03 | BB +1.1V IOH | ok | 1.28 | Volts
11/14/2008 | 13:58:04 | BB +1.1V P1 Vccp | ok | 0.84 | Volts
11/14/2008 | 13:58:04 | BB +1.1V P2 Vccp | ok | 0.84 | Volts