Appendix A: POST Codes QSSC-S4R Server System Product Guide
Version 1.0
160
The user needs to replace the faulty part and restart the system.
Major
The BIOS logs an error to the POST Error Manager.
The BIOS logs an error message to the BMC System Event Log (SEL).
The BIOS continues booting in a degraded state by default (i.e. BIOS does not automatically enter the POST
Error Manager to display the error message)
The user can override this default behavior by configuring the BIOS Setup POST Error Pause option to
Enabled. This forces the system to enter the POST Error Manager and display the error message before
booting.
The user can choose to take immediate corrective action or continue booting.
Minor
The BIOS logs an error to the POST Error Manager.
The BIOS continues booting with a degraded state (i.e. BIOS does not automatically enter the POST Error
Manager to display the error message).
The user may want to replace the erroneous unit.
The POST Error Manager reports a maximum of 500 errors on any single boot cycle. Errors are automatically
cleared from the Error Manager on each boot.
Table 53. POST Error Manager Messages and Handling
Error
Code
Error Message Response
0x0012 CMOS Date/Time not set. Major
0x0048 Password check failed. Major
0x0108 Keyboard locked error. Minor
0x0109 Keyboard stuck key error. Minor
0x0113
The SAS RAID firmware cannot run properly. The user should attempt to
reflash the firmware.
Major
0x0140 PCIe Parity Error (PERR). Fatal
0x0141 PCIe resource conflict error. Major
0x0146 PCIe out of resources error. Major
0x0192 Processor cache size mismatch detected. Fatal
0x0193 Processor stepping mismatch. Minor
0x0194 Processor family mismatch detected. Fatal
0x0195 Processor Intel(R) QPI speed mismatch. Major
0x0196 Processor model mismatch. Fatal
0x0197 Processor speeds mismatched. Fatal
0x0198 Processor family is not supported. Fatal
0x019F
Processor and chipset stepping configuration is unsupported. By continuing
to boot, you acknowledge you are operating in an unsupported
configuration.
Major
0x5220 CMOS/NVRAM configuration cleared. Major
0x5221 Passwords cleared by jumper. Major
0x5224 Password Clear jumper is set. Major
0x8120 Processor Thermal Trip error. Major