Ballrooms:
Each ballroom has a 12-pair and a four-pair cable home run to the central equipment room in a 1½-inch
conduit, an average run of 500 feet each. Total materials are 2,000 feet of 1½-inch conduit, 4,000 feet of 12-
pair, and 4,000 feet of 4-pair copper cable.
RAVE
In the RAVE system design, the microphone preamplifiers will be located in remote equipment closets.
Meeting rooms:
One 900-foot long ¾-inch conduit connects each of the north remote equipment closets and one
connects each of the south equipment closets for the meeting rooms. This is a total of 1800 feet of ¾-inch conduit
for the meeting rooms plus 4000 feet of 1½-inch conduit to connect the panels in the meeting rooms to the remote
equipment closets. Total cabling is 1,800 feet of 4-strand multimode fiber, 4,000 feet of 8-pair copper, and 4,000
feet of 4-pair copper.
Exhibit halls:
Each exhibit hall has one remote equipment closet with each two closets daisy-chained to a home
run to the central equipment room. Each exhibit hall has one local panel (150 feet from remote equipment closet)
and one or two other panels (500 feet from remote equipment closet). There is a total of 2,000 feet of ¾-inch