Specifications
17
Stadium analog system
Audio
processing
equipment
Analog audio
lines (typ.)
Central control room
1
1
16
16
1
1
16
16
100baseT
hub with
fiber-optic
I/O
Cable raceway
RAVE 161
(typ.)
PA-1
PA-2
PA-3
PA-n
¾" conduit,
fiber optic cable
Equipment room 1
100baseT
hub with
fiber-optic
I/O
RAVE 160
(typ.)
PA-1
PA-2
PA-3
PA-n
¾" conduit,
fiber optic cable
Equipment room 2
100baseT
hub with
fiber-optic
I/O
RAVE 160
(typ.)
PA-1
PA-2
PA-3
PA-n
¾" conduit,
fiber optic cable
Equipment room 3
100baseT
hub with
fiber-optic
I/O
RAVE 160
(typ.)
Stadium RAVE system
(solution A shown)
The analog solution
The analog design uses 4600 feet of 32-pair cables run between the control room and each equipment room in
2300 feet of 3-inch steel EMT conduit.
RAVE solution A
This solution uses existing cable tray, so the only conduit cost is 300 feet of ¾-inch conduit from the cable tray
to the equipment rooms. Cabling is 2300 feet of 4-strand multimode optical fiber.
RAVE solution B
Routed through 2300 feet of new ¾-inch conduit is 2300 feet of 4-strand multimode optical fiber.