Subsonic (high-pass) filter
Digital high-pass filter with Q programmable as flat
(.707) or B6 boost (2.0) from 15 Hz to 50 Hz
Automation inputs
CD Horn EQ
Digital shelf filter with up to ±10 dB of cut/boost
programmable from 20 Hz to 20 kHz
Input type OMNI (discrete state or potentiometer)
Screen EQ
Digital shelf filter with up to ±10 dB of cut/boost
programmable from 20 Hz to 20 kHz
Compatible sources
Accepts contact closure (switches, relays) or 10K
pot. Input is sampled and converted to 8-bit
digital value
All pass filter
2nd order all pass filter programmable from
20 Hz – 20 kHz
Logic Outputs
Band polarity Normal, inverted Output type Two-state logic
Band delay Programmable in 21μs steps from 0 ms to 10 ms Compatible CMOS compatible output levels
Channel delay
Programmable in 1ms steps from 0 ms to 175 ms
(0 to 4 frames)
Relay outputs
Master delay
Programmable in 1ms steps from 0 ms to 420 ms
(0 to 10 frames)
Output type Mechanical relay contacts
Mute Individual channel mutes, global mute Compatible
Max 30VDC output at 1A. Can be wired as N.O.
or N.C
Bass management
Weighted sum of screen channels may be low pass
filtered and mixed with sub output
Liquid crystal display
Surround bass management
Weighted sum of surround channels may be low
pass filtered and mixed with aux output A.
Display type Active color TFT
Amplifier A.C. Control
All amps power on with DCP activation and can
be placed into standby via user interface
Display area dimensions 4.3" diagonal viewing area
Monitor speaker Format 16 x 9
Speaker 4" full-range Touch panel type Resistive 4-wire
Impedance 4 Ohms Audio network
Amplifier output power 10 watts Class D Protocol CobraNet version 2 protocol
Frequency response 20 Hz – 20 kHz (± 2 dB) Data rate 100 Mbps (Fast Ethernet)
Dynamic processing 1.5:1 compression Ports 1 Primary, 1 Backup (auto-failover)
H.I. and V.I. impaired outputs Connection requirements
Cat-5 UTP cable or better (100m maximum
length), direct connection to wired network switch
ports only, dedicated LAN or VLAN
Output stage type Single ended (balanced Z) QSControl network / SNMP
Output impedance 50 Ohms Protocol
Standard TCP/IP implementation over Ethernet or
Fast Ethernet. 3rd party interface may use UDP/
IP or TCP/IP.
Nominal output level -11.8 dBu (200 mVrms) Data rate 10/100 Mbps
Loading requirements Rmin = 2k Ohms, Cmax = 4nF Connection requirements
Cat-5 UTP cable or better (100m maximum
length), direct connection to wired network switch
ports only, dedicated LAN or VLAN