Quick Start Manual
14
15
EN
DAB-801
Connectors
Input
Output
Other
6 position “Euro” or “Phoenix” type, QSC DataPort (HD-15), QSC GPIO (DB-15).
QSC DataPort (HD-15), 8 position high current “Euro” or “Phoenix” type.
Control Extension Bus (DB-37), IEC type AC Inlet.
Controls Page Assignment: 8 position “dip” type toggle switch.
Page/Alarm Inputs Balanced, 5k ohm, 3 Vrms.
LED Indicators POWER (blue, 1 each).
NORMAL (green, 8 each, 1 per primary DP).
FAULT (red, 8 each, 1 per primary DP).
BACKUP ACTIVE (yellow, 6 each, 1 per backup DP).
Maximum Amplifier Ratings 1200 W per channel
Power Requirements 100 – 240 VAC, 50 – 60 Hz, 12 W max.
Operating Temperature (Tma) 0°C – 40°C non condensing
Dimensions (HWD)
7" (17.8 cm) 4 RU x 19" (48.3 cm) rack mounting x 2" (5.1 cm)
Weight (net/shipping) 7.8 lb (3.5 kg) / 10.8 lb (5 kg)
Paging Section
Connection
The DAB-801 has two non-networked, analog paging inputs. Both of the
page inputs override all Q-Sys
TM
system inputs. The first input, located on a 6
position detachable header, is labeled “Page Input.” The second input, also
located on a 6 position detachable header, is labeled “Alarm Input.” An 8
position routing switch selects which amplifier channels receive the page or
alarm signal.
Page Priority
The “Page Input,” when enabled, will override all Q-Sys system inputs on the
selected channels. The “Alarm Input,” when enabled, will override both the
Page Inputs as well as the Q-Sys system inputs.
Extension Panel
Each panel must have its own Page/Alarm signals connected, and routing
switches set.
Dimensions
Specifications
19"
48.3 cm
2"
5.1 cm
7"