Technical data
7919A Paired - Category 5e DataTuff® Twisted Pair Cable
Outer Shield Drain Wire Stranding 7x32
Outer Shield Drain Wire Conductor Material TC - Tinned Copper
OUTER JACKET:
Outer Jacket Material Industrial Grade PVC - Polyvinyl Chloride
Outer Jacket Ripcord No
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .265 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range -40°C To +75°C
Installation Temperature Range -25°C To +75°C
Bulk Cable Weight 30 lbs/1000 ft.
Max. Recommended Pulling Tension 25 lbs.
Min. Bend Radius (Install) 1 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification CMR, CMX-Outdoor, UL444
CEC/C(UL) Specification CMR
IEC Specification 11801 Category 5
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
TIA/EIA Specification 568-B.2 Category 5e
Other Specification NEMA WC-63.1 Category 5e, UL verified to Category 5e
FLAME TEST:
UL Flame Test UL1666 Riser
CSA Flame Test FT4
SUITABILITY:
Suitability - Outdoor Yes
Sunlight Resistance Yes
Oil Resistance Yes
PLENUM/NON-PLENUM:
Plenum (Y/N) N
ELECTRICAL CHARACTERISTICS:
Nom. Mutual Capacitance @ 1 KHz 15 pF/ft
Maximum Capacitance Unbalance (pF/100 m) 330 pF/100 m
Nominal Velocity of Propagation 70 %
Maximum Delay (ns/100 m) 538 @ 100MHz ns/100 m
Page 2 of