INPUT SIGNAL PROCESSING
Frequency response 20 Hz–20 kHz ±0.5 dB 10 Hz–80 kHz ±3 dB
Distortion <0.01% THD+N @ +4 dBu out (page input <0.03%)
Dynamic range >110 dB unweighted 20 Hz–20 kHz (page input >100 dB)
Polarity In-phase or inverted
Level control range -95.5 to 0 dB in 0.5 dB steps
Precision attenuator better than 112 dB below transients (“zipper” maximum output noise)
Mute >90 dB attenuation
INPUTS
Program inputs 16
Paging inputs 1
Monitor bus input 1
Connector type Terminal block connectors (also called “Euro” or “Phoenix style”), detachable
Type Electronically balanced
Grounding All shield terminals connected to chassis
Nominal level 1V/3V rms selectable
Maximum level +21 dBu
Impedance 10 kOhm balanced
Common-mode rejection Typical, >50 dB, 20 Hz–20 kHz Worst Case, >40 dB at 20 kHz
Crosstalk (interchannel within DataPort pair) >75 dB separation, 20 Hz–20 kHz
Crosstalk (intrachannel, between DataPort pairs) >85 dB separation, 20 Hz–20 kHz, measured with all inputs and outputs terminated
OUTPUTS
Program outputs 16 (via HD-15)
Connector type 8 HD-15 DataPort connections
Pinout Special, see appendix
Cable type QSC DataPort Cable
Qualified length 2 meters
Monitor output 1
Connector “Phoenix-style” (a.k.a.“Euro-style”) detachable terminal blocks
Type Electronically balanced
Grounding Shield terminal connected to chassis
Nominal level +4 dBu
Maximum level +21 dBu
Output impedance 75 Ohms balanced
Output load 600 Ohms minimum
POWER AMPLIFIER OUTPUT PROCESSING/MONITORING
Output short detect* Senses load <1 Ohm for Stereo/Parallel modes; <2 Ohms in Bridged Mono mode. Threshold is adjustable in software
Output open detect* Senses load >60 Ohms. Threshold is adjustable in software.
Output voltage meter Range automatically matches to amplifier model used.
Output current meter Range automatically matches to amplifier model used.
Amp gain* Determines amplifier gain control setting, range automatically matches to amplifier model.
*Signal level must be greater than -32 dB, referenced to maximum output of amplifier
POWER AMPLIFIER MANAGEMENT
Power amplifier interface compatibility QSC DataPort equipped amplifiers
Connector and cable QSC DataPort cable, 2 meters length (for longer runs, contact QSC’s Technical Services Dept.)
Amplifiers 16 amp channels grouped in pairs
Amplifier status monitor Clip indicator Senses channel clipping
Bridge mode status Sense bridge mode setting
Protect indicator Senses amplifier protect status
Temperature meter Reports amplifier operating temperature
Over-Temp. Alert Software adjustable threshold
AC mode control Switches amplifier between normal and standby mode
AC power indicator Indicates operate, standby, or power-down mode