User Guide
PERFORMANCE
Dynamic Range (AES-17, -60 dB method, all sensitivities)  In  Out  Thru 
  Unweighted  > 112 dB   > 112 dB   110 dB 
  A weighted   > 115 dB   > 115 dB   113 dB
Distortion (20 Hz – 20 kHz, all sensitivities) 
  +4 dBu (maximum)  < 0.009% THD+N   < 0.009% THD+N   < 0.009% THD+N 
  2 dB below clip (maximum)   < 0.009% THD+N   < 0.009% THD+N   < 0.009% THD+N
Crosstalk (20 Hz – 20 kHz) 
  Inter-channel (maximum)   > 75 dB 
  Inter-channel (typical)   > 90 dB 
  Intra-channel (maximum)   > 85 dB 
  Intra-channel (typical)   > 100 dB
Frequency Response 
  20 Hz – 20 kHz (maximum)  +/- 0.5 dB 
  20 Hz – 20 kHz (typical)  +/- 0.2 dB
Audio Converters   24 bit, 48 kHz, in and out
Mute    Infinite attenuation
Delay    Standard CobraNet™ latency    Low latency 
  BASIS™ to Network  7.104 milliseconds    4.438 milliseconds 
 Analog input through full DSP chain to CobraNet output 
  Network to BASIS  6.313 milliseconds    3.646 milliseconds 
    CobraNet input through full DSP chain to analog output 
  BASIS to BASIS  8.083 milliseconds    5.417 milliseconds 
    Analog input through full DSP chain, over CobraNet network,  
  through full DSP chain, to analog outputs 
  BASIS in stand-alone mode  2.354 milliseconds (default group delay) 
 Analog input through full DSP chain to analog outputs 
INPUTS/OUTPUTS  
Program Inputs   4 inputs 
  Connector type   XLR/TRS combo 
  Type  Electrically balanced 
  Grounding  Shell and shield terminals connected to chassis 
  Pinout  2-Tip:+ / 3-Ring:- / 1-Sleeve: shield 
  Input Impedance (nominal)  Balanced: 10k ohms / Unbalanced: 10k ohms 
  Common-mode Rejection   20 Hz – 20 kHz (minimum): > 54 dB / 20 Hz – 20 kHz (typical): > 60 dB 
  Input Sensitivities (variable)  Vrms: 1.5, 3, 9, 18 / dBu: 5.7, 11.8, 21.3, 27.3 / dBV: 3.5, 9.5, 19.1, 25.1
Program Outputs  16 outputs 
  Connector Type   8 HD-15 DataPort connections 
  Cable Type  QSC DataPort cable, QSC p-n DPC-x (“x” designates cable length in feet) 
  Available “Stock” Lengths  1, 2, 3, 4, 5, 6, 10, and 20 ft., custom lengths available 
  Maximum Qualified Length  328 ft. (100 m) using QSC DP cable only / Non QSC cable limited to 6 ft. (audio only)
CONTROL INPUTS/OUTOUTS 
Omni Inputs   2 discrete inputs for TTL logic, voltage control or passive resistance 
  Connector Type   2-pin “phoenix style” (a.k.a. “euro style”) detachable terminal blocks 
  Configuration  Single-ended, ground referenced 
  Pinout  1:+(Signal) / 2:-(CHASSIS GND) 
  Normal Operating Range  Reads signals between 0-5 V nominally 
  Potentiometer Operation   Use 10k ohms for full range 
  Voltage Tolerance  +/- 48 V 
  Current Output   0.5 mA with 10k pot (for passive resistive controls)
RS-232 Port  Female DB9 connector (set and diagnostics purposes only)
QSControl Port  Neutrik Ethercon RJ45 ruggedized data connector
CobraNet Port   Neutrik Ethercon RJ45 ruggedized data connector
Indicators 
  QSControl Status   Yellow Link, Tx, Rx, front panel / Green Link, Tx, Rx, rear panel 
  CobraNet Status   Yellow Link, Tx, Rx, front and rear panel 
  Power  Blue, front panel 
  Diagnostic  Red, front panel 
  DataPort Status (port)  Tri-state (red, green, yellow), front panel 
  LCD Data Display  2 line x 16 character, backlit, front panel
BASIS 914lz
Specifications
qscaudio.com
Specifications subject to change without notice.
1675 MacArthur Boulevard • Costa Mesa, CA 92626 • Ph: 800/854-4079 or 714/957-7100 • Fax: 714/754-6174 
BASIS 914lz - 07/09/09