Stereo System User Manual
16
LED Indicators (continued)
QSControl and CobraNet Network Status (Port) Indicators- There are three LEDs on the front and rear panels labeled 
RX, TX and LINK. One group is for the QSControl network port and the other for the CobraNet network port. Their functions 
are described below. Note: Port indicators on rear panel are color coded to match the corresponding color-ring around the 
QSControl and CobraNet RJ45s.
RX (receive)- This indicator illuminates any time the RAVE 522aa receives data from the corresponding network.
TX (transmit)- This indicator illuminates whenever the RAVE 522aa transmits data onto the corresponding network.
LINK STATUS- The corresponding indicator illuminates when the RAVE 522aa is connected to an operating network.
LCD Display and Controls
The RAVE 522aa has a 2 line X 16 character LCD display. The display and the multi-function push-button switches on either 
side provide data access and editing capability. The push-button switches on either side of the display are used to navigate 
through the menus. The rotary select/accept knob is active for many displayed items allowing you to scroll through choices by 
rotating the control, and accepting choices (entering) by pushing in on the control.
The accessible menus and sub menus may appear differently than the example shown. Software updates may occasionally 
improve the interface. The basic navigation flow for the RAVE 522aa menu system is shown on the following page.
Front Panel Password Lockout
The password lockout provides the ability to restrict access to all of the editable parameters available on the LCD front panel. 
This feature is enabled or disabled via QSControl software only (refer to the “General Tab” area and click on the “Front Panel 
Password” button). When the lockout feature is enabled, all front panel LCD functions are readable, but editing of parameters 
is now password protected. While in this mode, any attempt to edit a parameter will require the user to enter the Front Panel 
Password. The default factory password is “qsc”. The password is stored in the RAVE unit and can be changed using the 
QSControl software.
Once the password has been correctly entered, the RAVE will allow edits to the parameters.
After 5 minutes of inactivity, the RAVE will automatically reset the Front Panel Password lockout. Re-entry of the password 
will be required to resume editing.
The lockout mode can be deliberately disabled via the “Disable Edits” checkbox in the Front Panel Password menu of the 
QSControl software.