Installaon Procedure
13
...Key Solenoid Plunger Throw
Step 3.Holdtheplungerinits"ON‐HOLD"posion.
This On‐Hold posion is where the TOP of the Plunger Body is flush with the
topofthesolenoid.
Posionagauge,apieceofwoodorcardboard,andmarkthelocaonoftop
of
thePlungerTip.
Releasetheplunger.
Step 5.TurntheKeySolenoidCaptomovethePlungerTiptoyourmark.
NOTE: If the cap won’t raise the plunger high enough because it isght
against the solenoid housing, no more threads, remove the plungers and
insertLost‐Moonfelt
washers.
Step ‐ Final.Adjustalllostmooncapstothesameposion.
Step 4.From the posion marked in step 3, use a ruler to measure the
Plunger Throw distance(step2)andmarkyourgauge.
Plunger Tip-Felt
Plunger Stem
Plunger Body
Key Solenoid
Solenoid Cap
Used to adjust Plunger Throw