User manual

102
iSCSI Quick C onfiguration Wizard
T he d e scriptio n be lo w a pplie s to In te l- b a se d NAS m o d e ls ru nning firm wa re v e rsio n 3.2.0
or la te r o nly .
Intel-based NAS refers to TS-239 Pro, TS-239 Pro II, TS-259 Pro, SS-439 Pro, TS-439 Pro, TS-439
Pro II, TS-439U-SP/RP, TS-459 Pro, TS-459U-SP/RP, TS-509 Pro, TS-559 Pro, TS-639 Pro, TS-659
Pro, SS-839 Pro, TS-859 Pro, TS-809 Pro, TS-809U-RP, and TS-859U-RP.
A maximum of 256 iSCSI targets and LUNs can be created. For example, if you create 100 targets
on the NAS, the maximum number of LUNs you can create is 156. Multiple LUNs can be created for
each target. However, the maximum number of concurrent connections to the iSCSI targets
supported by the NAS varies depending on your network infrastructure and the application
performance. Too many concurrent connections may slow down the performance of the NAS.
Follow the steps below to configure the iSCSI target service on the NAS.
1. Under the ‘Portal Management’ tab enable iSCSI target service. Apply the settings.
2. Next, go to theTarget Management’ tab and create iSCSI targets on the NAS. If you have not
created any iSCSI targets, the Quick Installation Wizard will show up and prompt you to create
iSCSI targets and LUN (Logical unit number). Click ‘OK’.