User`s guide

6HWWLQJ3DJH
)RUPDW
/13OXV(PXODWLRQIRU4063ULQWHUV
The HPR position cannot exceed the right margin.
+RUL]RQWDO3RVLWLRQ%DFNZDUG+3%
Use this sequence to move to the left on the current line relative to the
current position.
Syntax: <ESC>[
Pn
j
The HPB position cannot exceed the left margin.
9HUWLFDO3RVLWLRQ$EVROXWH93$
This sequence moves the current line vertically on the page.
Syntax: <ESC>[
Pn
d
The default value for
Pn
depends on the paper size used. The default
value for LTR size paper is 1. The default value for A4 size paper is 3.
9HUWLFDO3RVLWLRQ5HODWLYH935
This sequence moves the active line down relative to the current line
without changing the horizontal position.
Syntax: <ESC>[
Pn
e
Pn
A numeric value, expressed in units determined by
PUM and SSU settings, to subtract from the current
position. The default value of
Pn
is 1.
Pn
A numeric value for the new position expressed in
units determined by PUM and SSU settings. The
value for
Pn
is measured from the top margin.
Pn
A numeric value, expressed in units determined by
PUM and SSU settings, to add to the current position.
The default value is 0.