Specifications
Serial
Communication
QMS 4525 Print System Administrator's Guide4-6
Memory to an Interface” in chapter 7 for information about the Min K
Spool setting.
The printer is immediately restarted when a change is made to this
option. (For example, change the value to 35, press the Enter key,
and the menu changes. Press the Line key and the printer automati-
cally reboots.)
Spool Timeout
The Spool Timeout option sets the number of seconds the interface
waits for additional data from the host computer before terminating a
print job. The range is 00000 (no timeout) to 99999, and the default is
00030 seconds. If you change this setting, you must ensure that the
new setting does not conflict with the PS Wait Timeout and Emul Tim-
eout values.
If the Spool Timeout value expires before the printer has received all
data for a job it is spooling, the printer terminates the spooled print
job. You must turn the printer off and then on again before this change
takes effect.
End Job Mode
This option enables or disables data stream sensing for end-of-docu-
ment (EOD) terminator strings. These sequences allow hosts to
enforce print job sequencing without considerations for interacting
timeouts. The options are: None (the printer recognizes only the lan-
guage specific terminator commands such as the PostScript ^D com-
mand), QMS EOD (%%EndOfDocument), and HP EOD (<ESC>%-
12345X). Only one form of EOD may be used at a time. The default is
QMS EOD. This change takes effect immediately.
See the
QMS Crown Network Notes
manual that came with your
printer or the
End Job Mode on QMS Crown Printers
Application Note
available on Q-FAX (document number 7002), the bulletin board, and