Specifications

A Good Location
for Your Printer
QMS 4525 Print System Administrator's Guide1-6
A Good Location for Your Printer
Your QMS 4525 Print System requires an appropriate operating envi-
ronment.
Physical Requirements
The location should meet the following requirements:
Be away from cooling sources, heating sources, extreme temper-
ature changes, direct sunlight, excessive dust, and corrosive
chemicals or vapors.
Be away from any strong electromagnetic field (such as that cre-
ated by an air conditioner) and excessive vibration.
Have a temperature range of 41° F (5° C) to 95° F (35° C).
Have a relative humidity range of 30% to 80%.
Be well ventilated. You should have at least 24" (600 mm) on
each side of the printer for adequate access and ventilation.
Have a room volume of at least 883 feet
3
(25 meters
3
)
Have room ventilation of at least 442 feet
3
/hour (12.5 meters
3
/
hour). This minimum ventilation rate, with the minimum room vol-
ume given above, holds ozone buildup within acceptable levels.
To remove heat, additional ventilation may be required.
Be as close to the host as possible: 6 feet (approximately 1.8
meters) or less for parallel communication, 25 feet (approximately
7.5 meters) or less for serial communication.
Be level and capable of supporting the printer weight:
Printer with 20-bin sorter - 1,028 lbs (approx.)
Printer with 40-bin sorter - 1,124 lbs (approx.)
U.S. Electrical Requirements
Following are U.S. electrical requirements.
Single-phase 230 V (±10%); max. 16 A; 60 Hz (±2%)