User`s guide

Job Timeout (5 digits; default 00000; range 00000-99999)
Maximum number of seconds the printer processes a
print job before it ends the job.
ESP Timeout (5 digits; default 00003; range 00000-99999)
Maximum number of seconds the printer uses to match
an emulation before printing the job in the default
emulation.
Administration / Communications / Serial Sets the serial
interface communications values used for printer-host
communications.
Mode (default interactive; range interactive, noninteractive,
disabled)
Sets the PostScript emulation host mode. You must
turn the printer off and then on again before these
changes take effect.
Interactive Establishes two-way communication
between the host and the printer.
Noninteractive Establishes one-way communication
from the host to the printer.
Disabled Turns off serial interface communica-
tion with the printer. The printer stops
accepting serial interface print jobs.
Emulation (default ESP; range ESP, Hexdump, PCL4, HPGL,
PostScript)
Selects the serial interface emulation. Optional
emulations appear, if installed.
Min K Spool (5 digits; default 00015; range 00000-99999)
Sets the minimum number of kilobytes of system
memory allocated to the serial interface. A 00000 value
does not turn off the serial interface’s spooling buffer.
If the value is 00000, the printer calculates the Min K
Spool value at initialization.
Prerequisite: Value must be less than K Mem for
Spool.
Chapter 4
4-26 Printer Configuration