Specifications

#
&

Sets the binary communication protocol (BCP) for communicating over a LocalTalk
interface to a PostScript printer. See chapter 3, “Additional Technical Information,for
a full discussion of PS Protocol.
,0.$
Allows you to specify which jobs are printed first, according to the interface through
which they are received, when jobs are received simultaneously. In other words, you
can give jobs received via the LocalTalk interface priority over jobs received via the
parallel or optional serial interface.
Menu
Administration/Communications/LocalTalk/PS Protocol
Choices
Normal—Enables standard, ASCII (7-bit) hex protocol. Data is sent and
received in ASCII format. This mode is recommended if you do not print
binary data. It was designed for data in the printable ASCII range. Print
jobs can change this setting through PostScript operators.
Normal Fixed—Enables standard, ASCII (7-bit) hex protocol. Print jobs
cannot change this setting through PostScript operators.
Binary—Enables binary communications protocol (BCP). Print jobs can
change this setting through PostScript operators. Data in the printable
ASCII range also prints.
Binary Fixed—Enables binary fixed communications protocol (BCP). Print
jobs cannot alter change this setting through PostScript operators. Data
in the printable ASCII range also prints.
Default
Normal
Notes
See chapter 5, “Additional Technical Information,” of the
Reference
manual for a full discussion of PS Protocol.
Menu
Administration/Communications/LocalTalk/Def Job Prio
Choices
001-100 (highest-lowest priority)
Default
001 (highest priority)