Service manual

QMS 3260/4032 Laser Printer - Base Engine Technical Manual 10-119
Release Version 11-97
Removal and Replacement Procedures
RRP 7.7 Lower Chute Assembly (PL 9.1)
Removal
1. Remove the Offset Roller Assembl
y
(
RRP 7.6
)
.
2. Remove the five screws securin
g
the Lower Chute to the Exit Assembl
y
frame, and separate the
Lower Chute from the frame.
3. Release J104 wire harness from the harness clips.
4. S
q
ueeze the latches to unlock the Fuser Exit Sensor, and remove the Sensor from the Lower Chute.
Replacement
1. Reinstall the Fuser Exit Sensor b
y
pressin
g
the Sensor latches into the cutouts in the Lower Chute.
Make sure
y
ou install the Sensor with the wire harness positioned to the rear of the Lower Chute, and
the Sensor actuator movin
g
freel
y
thou
g
h the cutout below the Sensor.
2. Secure J104 wire harness under the harness clips located on the Lower Chute.
3. Reinstall the Lower Chute to the Exit Assembl
y
frame.
4. Use five screws to secure the Lower Chute.
5. Reinstall the Offset Roller Assembl
y
(
RRP 7.6
)
.