Service Messages
Service calls should be placed to the vendor from whom you purchased
the printer. If you cannot get service from your vendor, see Support Info for
more information.
»Note:
A service message sometimes occurs as a result of an unusual combination of
events, not because of an actual problem. When the printer stops and a service
message displays in the message window, turn the printer off and then back on. This
often clears the service message indicator, and printer operation resumes. Always try
this before making a service call.
This service message...
Means...
SERVICE CALL MEMORY-04
Malfunction of built-in RAM, read/write is detected
SERVICE CALL MEMORY-06
Nonvolatile memory is broken down
SERVICE CALL MEMORY-10
Malfunction of nonvolatile memory, read/write is detected
SERVICE CALL FUSER-02
A timing error is detected in fuser.
SERVICE CALL FUSER-04
Fuser temperature reaches 250° or more.
SERVICE CALL FUSER-06
Temperature thermistor disconnection is detected.
SERVICE CALL FUSER-15
Fuser fan failure is detected.
SERVICE CALL ROS-02
ROS ASIC failure is detected.
SERVICE CALL ROS-06
BD signal transmission interval is longer than a specified value.
SERVICE CALL ROS-10
BD signal transmission interval is shorter than a specified value.