Specifications

C-17
PagePro25
Fusing temperature control:
When the power switch is turned ON, the printer starts warm-up until the upper fusing roller temperature reaches
approx. 200°C. (It will take about one minute.) (Warming-up mode)
To maintain the upper fusing roller temperature above 190°C, the control circuit raises the temperature and keeps at
approx. 210°C for approx. five minutes. (Mode 1)
The control circuit gradually decreases the temperature by 190°C in five minutes. (Mode 2)
Preparing for printing, the control circuit keeps the upper fusing roller temperature at approx. 190°C. (Mode 3)
In energy saving mode, the control circuit turns OFF the heater lamp.
(*: 190°C --> 183°C for foreign model??)
1 min. 5 min. 5 min.
Mode 1 Mode 2 Mode 3
Heater OFF
Power ON
Warm-up
Energy
Save
Temp. for Standby
Temp. for Print
°C
210
200
190
Power ON
Heater OFF
Temp. for Print
Temp. for Standby
Energy
Save
Mode 3
Mode 2Mode 1
Warm-up
1 min.
5 min.
5 min.
210
200
190
°C
Lower Fusing Roller
Paper
Thermostat (TS1)
Thermistor (TH1)
Heater Lamp Fuse (TF1)
Upper Fusing Roller
(Heater Lamp (H1))