Specifications
B-7
PagePro25
(3) Service Mode Tree
*: Default setting
[ ]: Displayed when the option is installed.
(4) Explanations for Items in the Service Mode
In the Service mode, you can display counter values or reset the counters. The counter value for I/C COUNT is stored in
the EEPROM in the engine. Other counter values are stored in the EEPROM in the controller (controller board).
TOTAL COUNT:
The total number of printed sheets after delivery from the factory is displayed in 7 digits. You cannot clear this
counter.
LARGE SIZE COUNT:
The total number of printed sheets for A3 and ledger after delivery from the factory is displayed in 7 digits. You cannot
clear this counter.
STAPLE COUNT:
The number of times an optional stapler has been used is displayed in 6 digits.
To reset the counter, select “RESET COUNT” with the Select key and press the Enter key. “RESET OK?” will be dis-
played on the LCD. Press the Enter key again to clear the counter.
I/C COUNT:
The number of times the PC drum in the imaging cartridge has been turned is displayed in 6 digits.
To reset the counter, select “RESET COUNT” with the Select key and press the Enter key. “RESET OK?” will be dis-
played on the LCD. Press the Enter key again to clear the counter.
LOOP ADJUST T2-5, LOOP ADJUST T1, [LOOP ADJUST DUP]:
The loop value for tray 2 - 5, tray 1, and optional manual unit and duplex unit can be adjusted. The loop value set here
will affect the registration compensation for paper (paper skew compensation). If registration is not correctly made,
the loop value should be adjusted to correct it. (For registration compensation, see 2-3 “Paper Feed” in C “MECHAN-
ICAL/ELECTRICAL”.)
SERVICE MESSAGE:
In the default setting (“ON”), the Maintenance Menu will be displayed normally. If “PERMANENT OFF” is set, no
items and no “MAINTENANCE REQ#” will be displayed even if the Maintenance Menu is selected.
Menu
Item Option
SERVICE MENU TOTAL COUNT 0000000 - 9999999
LARGE SIZE COUNT 0000000 - 9999999
STAPLE COUNT 000000 - 999999
RESET COUNT
I/C COUNT 000000 - 999999 (??What display for “Limit”??)
RESET COUNT
LOOP ADJUST T2-5 -4.9, -4.2, -2.8, -2.1, -0.7, 0*, +0.7, +2.1, +2.8, +4.2, +4.9 mm
LOOP ADJUST T1 -4.9, -4.2, -2.8, -2.1, -0.7, 0*, +0.7, +2.1, +2.8, +4.2, +4.9 mm
[LOOP ADJUST DUP] -4.9, -4.2, -2.8, -2.1, -0.7, 0*, +0.7, +2.1, +2.8, +4.2, +4.9 mm
SERVICE MESSAGE PERMANENT OFF, ON*