Owner's manual

Heater Check-Out and Operation
1. Turn the thermostat that is provided to control the heater to
the full counter-clockwise direction (LO or OFF setting).
2. Turn power to heater ON at main service panel.
3. Check heater to confirm it is not operating.
4. Turn thermostat to the full clockwise positon (HI setting).
This should energize the heater. In a short time, the fan
should come on and warm air should flow from the heater.
NOTE: This heater is provided with a fan delay control that
allows the heating element to warm prior to the fan coming
on. This delay will also allow the fan to operate for a short
period after the heating element has been turned off to
remove the residual heat from the heater.
5. After the room has reached the desired temperature, adjust
the thermostat back to the desired temperature setting. In a
short time, the fan should turn off.
NOTE: For the best results, the heater should be left “ON”
constantly during the heating season as the thermostat,
when properly set, will maintain the desired temperature.
Maintenance and Cleaning
Maintenance
Your heater is designed for years of trouble-free operation and
requires no special maintenance other than occasional clean-
ing. The motor is permanently lubricated.
Cleaning
Once each year, the heater should be cleaned to remove dust
and other foreign material which has collected during the heat-
ing season, as follows:
1. Turn power off at main switch.
2. Remove grille by removing four screws and turn disconnect
switch to the “OFF” position.
3. Use vacuum cleaner with brush attachment to remove dust
and dirt that has accumulated in heater (especially around
heating element and fan blade). Do not use water or any
cleaners to clean heater components.
4. After cleaning, turn disconnect switch to the “ON” position.
5. Replace grille.
6. Wipe grille clean with a damp cloth. DO NOT use waxes or
any cleaners that leave a residue since these may discolor
during heater operaton.
7. Turn the main line switch on at the switch panel to restore
power to heater. The heater is now ready for another season
of operation.
Ref. No. Description Part Number
1 Back Box 1203-2015-000
2 Front Cover 1402-2149-000
3 Motor, 208V 3900-2010-000
3 Motor, 240/277V 3900-2010-001
3 Motor, 120V 3900-2010-003
4 Fan Panel 4513-2042-000
5 Motor Mount 310914002
6 High Limit 410169001
7 Fan Delay 410074000
8 Disconnect Switch 410170001
9 Disconnect Switch Bracket 1215-2058-000
10 Element-1500W, 120V 302012827
Ref. No. Description Part Number
10 Element-1500W, 277V 302015006
10 Element- 2000W, 208V 302015001
10 Element- 2000W, 240V 302015002
10 Element- 2000W, 277V 302015003
10 Element- 3000W, 277V 302012006
10 Element- 4000W, 208V 302012007
10 Element- 4000W, 240V 302012008
10 Element- 4000W, 277V 302012009
10 Element- 4800W, 240V 302012010
10 Element- 4800W, 277V 302012011
11 Fan Blade 490030103
12 Wire Compartment Cover 4513-2037-000
NOTE: Always order by “Part Number”, never by “Ref. No.”
Renewal Part Indentificaiton
1
8
9
5
3
11
7
6
10
4
2
12
3