Mounting Guide
INSTALLATION OF MOUNTING BRACKETS
VDMB5, VDMB20, VDMB50, 3UG05, 3UG06, 3UG08,
2YU83, 2YU84 and 2YU85
1. Locate the position of the vertical discharge mounting bracket. Refer to
Figure 4 for minimum mounting clearances. Refer to Figure 8 for brack-
et dimensions.
2. A minimum screw size 3/8” diameter should be used to mount two of the
brackets to the ceiling. A heavy washer should be used between the
bolt head and the bracket. Use the type of screw that is best suited
to the building structure.
3. Remove four bolts and washers from the back of the heater and secure
the other two brackets to the back of the heater using the four bolts and
washers.
4. Bolt the unit mounted brackets to the ceiling mounted brackets using the
3/8” bolts, split lockwashers and nuts provided. See Figure 8.
INSTALLATION OF CMB MOUNTING BRACKETS
1. Mount bracket per step 4 of Installation of Mounting Brackets, page 1.
2. Hang heater from ceiling using center hole in unit mounting bracket,
maintaining clearances shown in Figure 4.
THE BUILDING STRUCTURE AND THE ANCHORING PROVISIONS
MUST BE SUFFICIENT TO SUPPORT THE COMBINED WEIGHT OF
THE HEATER AND MOUNTING BRACKET.
WARNING
6/09 ECR 38318
5200-2303-502
2
V
Q
C
EILING
S
IDE
W
ALL
V
Q
H
Q
C
EILING
S
IDE
W
ALL
C
EILING
B
ACK
W
ALL
B
RACKET TO SIDE BRACKET TO REAR
B
RACKET TO REAR
H
EATER HEATER HEATER
Minimum Mounting Clearances For Horizontal Discharge
Heaters Ceiling Side Wall Back Wall H (Min.) V (Min.) Q
3 KW - 5 KW 2” (51mm) 6” (152mm) 9” (229mm) 13” (330mm) “0” 18
3
/
16
” (462mm)
7.5 KW - 10 KW 6” (152mm) 6” (152mm) 13” (330mm) 15
1
/
2
” (394mm) 2” (50mm) 27
7
/
8
” (708mm)
15 KW - 20 KW 6” (152mm) 9” (229mm) 12
1
/
2
” (318mm) 18
1
/
2
” (470mm) 2” (50mm) 27
7
/
8
” (708mm)
25 KW - 50 KW 16” (406mm) 12” (305mm) 18
1
/
2
” (470mm) 25
1
/
2
” (648mm) 10
5
/
8
”
(270mm)
46
3
/
16
” (1173mm)
Figure 4. Mounting Bracket Clearances
3/4"
C
D
1
-1/2"
L
B
A
E
M
1-1/2"
Figure 5. Mounting Bracket Hole Dimensions
Heater Size
Dimensions 3-20 KW 25-50KW
A7
1
/
4
” (184mm) 9
7
/
16
” (240mm)
B9
1
/
2
” (241mm) 14
3
/
8
” (365mm)
C7
1
/
4
” (184mm) 12
1
/
8
” (308mm)
D1
15
/
16
” (49mm) 2
1
/
16
” (52mm)
E2
1
/
4
” (57mm) 3” (76mm)
L 20
1
/
2
” (521mm) 28
5
/
16
” (719mm)
M9
15
/
16
” (253mm) 14
15
/
16
” (380mm)
Model No. Used on
B10, 6X966, 2YV16 3 - 10 KW
B20, 6X967, 2YV17 15 - 20 KW
B30, 3UG64, 2YU91 25 - 30 KW
B50, 3UG65, 2YU92 40 - 50 KW
UNIT MOUNTING
BRACKET
OPENING MUST FACE
REAR OF HEATER
WASHER
MOUNTING BOLTS
H
EA
TER
FRO
NT
Figure 6. Installation of Unit Mounting Bracket
Catalog No. Used on
CMB-10 3 - 10 KW
CMB-20 15 - 20 KW
CMB-30 25 - 30 KW
CMB-50 40 - 50 KW
AA
BB
HEATER
BACK
5/16" BOLTS,
LOCKWASHERS
AND NUTS
(4 LOCATIONS)
BRACKET
ATTACHMENT BOLT
(4 LOCATIONS)
Figure 8. Installation of Heater on Mounting Bracket
Model No. KW AB
VDMB5, 3UG05, 2YU83 3 - 5 KW 6” (152mm) 6
1
/
8
” (156mm)
VDMB20, 3UG06, 2YU84 7.5 - 20 KW 8
7
/
8
” (225mm) 6
1
/
8
” (156mm)
VDMB50, 3UG08, 2YU85 25 - 50 KW 12
1
/
2
” (318 mm) 12
1
/
8
” (308mm)
3/8” BOLTS
WALL MOUNTING
BRACKET
CEILING MOUNT
1
/2-13
NUT
1/2"
SPLIT
L
OCKWASHER
1
/2"
FLAT WASHER
1/2"
FLAT WASHER
1/2-13
B
OLT
Figure 7. Installation of Heater on Mounting Bracket
470 Beauty Spot Rd. East