Owner manual

TO RESET MANUAL RESET LIMIT:
Your heater is equipped with a manual reset safety thermal limit control
that will automatically turn the heater off to prevent a fire if the heater over-
heats. This control is located on the fan panel assembly between the ele-
ment and fan blade and marked “reset”. The red reset button can be seen
through the front grille when the heater is installed. To reset, allow the
heater to cool, then push the red button that is visible through the hole in
the fan panel. The heater should immediately return to normal operation.
ELEMENTS
FAN
MOTOR
FAN
DELAY
RELAY
DISCONNECT
FIELD WIRING
GND
THERMOSTAT
MANUAL
RESET
CYC
L1
1
6
8
4
6
2
1
3
2
Wiring Diagrams
W
IRING DIAGRAM FOR THREE PHASE WALL HEATERS
1500, 1800,4800, 4000, & 3000 WATT HEATERS
120V, 208V, 240V, OR 277V (See diagram no.2 for 4800W, 208V 1Ph)
(Full wattage heaters can be converted to half wattage by moving the red
jumper wire connecting the top and bottom element terminals.)
NOTE: Conversion not applicable to 120V models.
2000 & 1500 WATT HEATERS
208V, 240V, OR 277V
4800, 4000 & 3000 WATT HEATERS
347V OR 600V
TRANSFORMER
DISCONNECT
DISCONNECT
M
ODEL NO.
WH45083 D
ATE CODE:
0206
FAN FORCED WALL HEATER
A
PPAREIL DE CHAUFFAGE MURAL À AIR PULSÉ
V
OLTS AC 60HZ WATTS PHASE
HI LO
2
08 4800 3
MUST BE USED WITH AWH-BB BACK BOX
D
O NOT OPERATE WITHOUT FRONT COVER IN PLACE.
DOIT ÉTRE UTILISÉ AVEC BOÎTIER ARRIÈRE AWH-BB
N
E PAS UTILISER SI LE COUVERCLE AVANT NʼEST PAS EN PLACE.
MARLEY ENGINEERED PRODUCTS
BENNETTSVILLE, SC 29512
774G LISTED
ROOM HEATER
NAMEPLATE
4
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5