zone name XD-Xen-Server-2-fc0 vsan 100
* fcid 0x47002e [pwwn 20:00:00:25:b5:0a:ad:3c]
* fcid 0x470200 [pwwn 50:0a:09:83:89:1a:b9:d9]
* fcid 0x470300 [pwwn 50:0a:09:81:89:1a:b9:d9]
Where 20:00:00:25:b5:0a:ad:3e/20:00:00:25:b5:0a:ad:2e are server‘s pwwn of the CNA that are part of the Fabric
A side. Similar zoning is done on the corresponding Nexus 5500 series switch pair to take care of the Fabric B
side as shown below.
N5K-B# sh zoneset active vsan 100
zoneset name FAB-B-XD-XS-BFS vsan 100
zone name XD-Xen-Server-1-fc1 vsan 100
* fcid 0x47002e [pwwn 20:00:00:25:b5:0a:ad:2e]
* fcid 0x470500 [pwwn 50:0a:09:81:99:1a:b9:d9]
* fcid 0x470400 [pwwn 50:0a:09:83:99:1a:b9:d9]
zone name XD-Xen-Server-2-fc1 vsan 100
* fcid 0x470735 [pwwn 20:00:00:25:b5:0a:ad:2c]
* fcid 0x470500 [pwwn 50:0a:09:83:99:1a:b9:d9]
* fcid 0x470400 [pwwn 50:0a:09:81:99:1a:b9:d9]
The NetApp Fibre Channel target ports, 50:0a:09:83:89:1a:b9:d9/50:0a:09:83:99:1a:b9:d9 belong to one
controller and 50:0a:09:81:99:1a:b9:d9/50:0a:09:81:89:1a:b9:d9 was part of the second controller. They were
spread across the two controllers for redundancy as shown in Figure 43.