Product specifications
3 – FVIC Configuration and Monitoring Features
Fibre Channel Configuration
D000003-016 Rev. A 3-27
A
NOTE:
The Virtual Port Key can be found on a label attached to the FVIC.
Figure 3-46 FC Virtual Port Key
NOTE:
Once the Virtual Port Key is entered, it becomes a part of the FVIC
configuration. The configuration should be backed up using the menu
options Config File Admin, Administer, Backup (see “Configuration File
Administration” on page 2-32 for detailed information). Once the
configuration is saved, if the FVIC is removed and replaced with a different
FVIC in the same slot, the new FVIC will contain the Virtual Port Key of the
initial FVIC.
5. To configure a virtual port, click on a row in the FC Virtual Port Configuration
window.
Figure 3-47 FC Virtual Port Key Window
6. Enter a port name in the Name text box.
7. In the Port dropdown, select an FVIC port to assign to the virtual port (choices
are port 1 through 8, or Unassigned).
8. In the Status dropdown, select Active or Inactive.
9. At the bottom of the window, click Apply.