Product specifications
3 – FVIC Configuration and Monitoring Features
Fibre Channel Configuration
3-14 D000003-016 Rev. A
S
3. Click on FCP Device Discovery. The Fibre Channel Target Device
Configuration window is displayed:
Figure 3-22 Fibre Channel Target Device Configuration Window
Any devices listed in the Configured Devices table have been previously
discovered and configured. The devices must have a status of Connected in
order to be utilized by an SRP Initiator. A device will have a status of Down if it
is no longer logically connected to the FVIC port listed in the Port column. For
example, if the FVIC previously discovered the device through Port 1, and the
Fibre Channel cable has been moved to Port 2, the device will be displayed as
Disconnected.
4. If the desired device and FVIC port does not appear in the Configured Devices
table, click Start. All newly discovered devices are displayed in the Discovered
Devices table.
NOTE:A device will appear for each FVIC port connected to the same fabric
(e.g., multiple FVIC ports are connected to the same Fibre Channel switch).
Figure 3-23 Discovered Devices Table